SERVICE MANUAL
Figure 5-44. SVC6F High Voltage Power Alarm Flow Chart (2 of 3)
5-98
a
Check the ground connection
below the transfer guide unit.
Ground
No
connection is
good.
Yes
Check that the spring loaded
grounding clips are contacting
the transfer corona frame,
Grounding
No
clips are contacting
the frame.
Yes
Remove the drum unit. Check
the precharger high voltage
contact spring located on the
inside rear wall of the printer.
The
high voltage
No
contact spring
making good
contact.
Yes
b
Clean ground connection.
Verify repairs.
SVC6F
error still
occur?
Yes
Retention clips. Verify
repairs.
SVC6F
error still
occur?
Yes
Retention spring. Verify
repairs.
SVC6F
error still
occur?
Yes

Advertisement