3 SPECIFICATIONS

3.6 Input/output signals for master module

3.6.1 List of input/output signals

Signal direction Master module
Device No. (input)
RXn0
Transmission normal complete
RXn1
Transmission error complete
RXn2
Reception normal read request
RXn3
Reception error read request
RXn4
Initialization normal complete
RXn5
Initialization error complete
RXn6
OS reception area clear complete
RXn7
EEPROM function normal complete
RXn8
EEPROM function error complete
RXn9
Signal status
RXnA
RXnB
RXnC to RXnD
General-purpose external input signal
RXnE to RX(n+1)8
Use prohibited
RX(n+1)9
Initial data read complete
RX(n+1)A
Error state
RX(n+1)B
Remote station ready
RX(n+1)C to
Use prohibited
RX(n+1)D
RX(n+1)E
Intelligent device station access complete
RX(n+1)F
Use prohibited
*1
The RS signal setting is valid when the "RS signal status designation ( R 2 101
RYn9 ON/OFF (1)". (Refer to section 8.9.)
*2
The ER signal setting is invalid when the "Flow control designation ( R 2 100
flow control. (DTR/DSR/ (ER/DR) control) (1)".
The input/output signals (RX/RY) for the R2 master module are explained in this
section.
A list of the R2 input/output signals is shown below.
R2
Signal name
CS (CTS) signal
DR (DSR) signal
CD signal
Important
Do not designate the RXn0 to RXn8, RXnE to RX(n+1)F, RYn0 to RYn9, RYnB, or RYnE to
RY (N+1)F signals to the following functions.
Monitor target RX/RY for monitor transmission function
Reference RX/RY for registration frame RX/RY/RW reference special character.
Do not output (turn ON) the usage-prohibited signals.
If an output is carried out to a usage-prohibited signal, the programmable controller system
could malfunction.
Signal direction Master module
Device No. (output)
RYn0
RYn1
RYn2
RYn3
RYn4
RYn5
RYn6
RYn7
RYn8
RYn9
RYnA
RYnB
RYnC to RYnD
RYnE to RY(n+1)8
RY(n+1)9
RY(n+1)A
RY(n+1)B to RY(n+1)D Use prohibited
RY(n+1)E
RY(n+1)F
n: Address assigned to master module with station No. setting.
3 - 7
MELSEC-A
R2
Signal name
Transmission request
Transmission cancel request
Reception read complete
Forced reception complete request
Initialization request
Use prohibited
OS reception area clear request
EEPROM function request
Use prohibited
RS (RST) signal *
Signal setting
ER (DTR) signal *
Use prohibited
General-purpose external output signal
Use prohibited
Initial data read request
Error reset request
Intelligent device station access request
Use prohibited
)" is set to "Follow
H
)" is set to "Carry out
H
1
2