Mitsubishi MELSEC AJ65BT-R2 User Manual page 53

Rs-232c interface module type
Hide thumbs Also See for MELSEC AJ65BT-R2:
Table of Contents

Advertisement

4 PROCEDURES AND SETTINGS BEFORE OPERATION
No.
Name
(2) Station No. setting switch
(3) Data link transmission speed
setting switch
(4) Mode setting switch
(5) RS-232-C transmission
specifications setting switch
(6) Data link terminal block
(7) RS-232-C interface
(8) General-purpose input/output
terminal block.
(9) Reset switch
(10) Connector
Set the module's station No. (Default setting: 0)
Setting range: 1 to 64 (0: Master module)
" 10" sets the 10th place of the station No..
" 1" sets the 1st place of the station No..
Setting
Transmission speed
0
156kbps
1
625kbps
2
2.5Mbps
3
5Mbps
4
10Mbps
-
Setting error
Set the module's operation state. (Default setting: 0)
No.
Name
On-line mode (using
0
transmission/reception buffer)
On-line mode (using buffer memory
1
automatic update function)
2 Not used
3 Not used
4 Use not possible
5 Not used
6 Not used
7 Not used
8 Not used
9 Not used
A Not used
B Not used
C Not used
D Hardware test mode
E Not used
F Not used
Set the RS-232-C transmission specifications.
No.
Setting details
SW1 to 3 Transmission speed
SW4
SW5
Data bit length
SW6
Parity bit
SW7
SW8
Stop bit length
Connect a CC-Link dedicated cable for power supply and data link. (2-piece terminal
block)
Connect an RS-232-C cable for connection with external device.
Connect the input/output wire.
Returns to the power ON status.
Use prohibited.
4 - 7
Details
Set the module's transmission speed (for data
link)
(Default setting: 0)
Setting details
Mode for on-line communication.
Set when using the transmission/reception buffer.
Mode for on-line communication.
Set when using the buffer memory automatic update function.
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Mode for confirming that module runs independently.
Setting error ("RUN" LED turns OFF.)
Setting error ("RUN" LED turns OFF.)
Setting switch state
ON
SW
1
2
0
0
1
0
0
1
1
1
0
0
1
0
0
1
0:OFF 1:ON
Not used
8
Yes
Even
2
MELSEC-A
Default
OFF
setting
3
0
300bps
0
600bps
0
1200bps
0
2400bps
OFF
1
4800bps
1
9600bps
1
19200bps
7
ON
No
Odd
OFF
1