A-1-2
Characteristics
Indication accuracy
(ambient temperature of
23°C)
Temperature variation
*2
influence
*2
Voltage variation influence
Hysteresis
Proportional band (P)
*
3
Integral time (I)
*
3
Derivative time (D)
Control Period
Manual reset value
Alarm setting range
Sampling cycle
Insulation resistance
Dielectric strength
Malfunction vibration
Vibration resistance
Malfunction shock
Shock resistance
Weight
Degree of protection
Memory protection
The indication accuracy of K, T, and N thermocouples at a temperature of −100°C or less is ±2°C ±1 digit maximum.
*1
The indication accuracy of U and L thermocouples is ±2°C ±1 digit maximum.
The indication accuracy of B thermocouples at a temperature of 400°C or less is not specified.
The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C maximum.
The indication accuracy of R and S thermocouples at a temperature of 200°C or less is ±3°C ±1 digit maximum.
The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit maximum.
The indication accuracy of PLII thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit maximum.
Ambient temperature: −10°C to 23°C to 55°C
*2
Voltage range: −15 to +10% of rated voltage
*3
The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
Digital Temperature Controllers (Simple Type) User's Manual (H211)
(±0.3% of PV or ±1°C, whichever is greater) ±1 digit max.
*
1
Thermocouple
(±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit max.
Resistance
thermometer
±0.2% FS ±1 digit max.
Analog input
±5% FS ±1 digit max.
CT input
Thermocouple (R, S, B, W, PLII)
(±1% of PV or ±10°C, whichever is greater) ±1 digit max.
Thermocouple
Other thermocouples:
(±1% of PV or ±4°C, whichever is greater) ±1 digit max.
*K thermocouple at −100°C max: ±10°C max.
(±1% of PV or ±2°C, whichever is greater) ±1 digit max.
Resistance
thermometer
±1% FS ±1 digit max.
Analog input
±5% FS ±1 digit max.
CT input
0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Temperature input
Analog input
0.01% to 99.99% FS (in units of 0.01% FS)
0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Temperature input
Analog input
0.1% to 999.9% FS (in units of 0.1% FS)
0 to 9,999 s (in units of 1 s)
0.0 to 999.9 s (in units of 0.1 s)
0 to 9,999 s (in units of 1 s)
0.0 to 999.9 s (in units of 0.1 s)
0.1, 0.2, 0.5, or 1 to 99 s (in units of 1 s)
0.0% to 100.0% (in units of 0.1%)
−1,999 to 9,999 (decimal point position depends on input type)
50 ms
20 MΩ min. (at 500 VDC)
2,300 VAC, 50/60 Hz for 1 min between terminals of different charge
10 to 55 Hz, 20 m/s
10 to 55 Hz, 20 m/s
100 m/s
300 m/s
Approx. 120 g
E5CC
Approx. 210 g
E5EC
Front panel: IP66, rear case: IP20, terminals: IP00
Non-volatile memory (number of writes: 1,000,000)
2
for 10 min each in X, Y and Z directions
2
for 2 hr each in X, Y, and Z directions
2
, 3 times each in X, Y, and Z directions
2
, 3 times each in X, Y, and Z directions
Adapter:
Approx. 10 g
Adapter:
Approx. 4 g × 2
A Appendices
A
Terminal cover:
Approx. 0.5 g each
Terminal Cover:
Approx. 1 g each
A - 3