Plumbing Connections; Gas Connection - Ferroli KONA 12 Operating Instructions Manual

Low nox
Hide thumbs Also See for KONA 12:
Table of Contents

Advertisement

Available languages

Available languages

KONA
KONA 12
0DK96KAA
B32-C12-C22-C32-C42-C52-C62-C82-C92
II2HM3B/P (IT)
II2R3R (FR)
II2Esi3P (FR)
II2ELwLs3B/P (PL)
3P - G31 - 37 mbar
Qn (Hi)
=
Pn - Pmin
=
tmax =
65
°C
NOx 6 (< 56 mg/kWh)
0085 / 22
8
230 V ~ 50 Hz
34 W
For outdoor installation in partially protected place
Temp. min.: -5 °C
MADE IN SPAIN
Fig. 1 - Data plate

2.4 Plumbing connections

Never place the water heater down on the
water / gas connections. Carry out the
connections according to the dimensions
and connections given in Section 4.1.
The inlet (water and gas) and water outlet connections are identified on the
bottom of the unit. They are all 1/2".
Ser. n.: 2219LE9006
II2H3B/P (IE)
II2H3P (GB)
II2Er3P (FR)
max
-
min
23
-
4
kW
20.9
-
3.6
kW
=
10
bar
pw
D
=
10
l/min
H
O
2
430709
516557
2219LE9006
IPX4D
A73023750 - Rev. 01 - 02-2023
SYMBOL
DESCRIPTION
WATER inlet symbol
GAS inlet symbol
HOT WATER outlet symbol
In case of water harder than 25 °fH (1
°fH = 10 ppm CaCO3), use suitably treated
water in order to avoid possible scaling in
the unit.

2.5 Gas connection

Before making the connection, check
that the unit is arranged for operation
with the type of fuel available and
carefully clean all the system pipes
to remove anything able to affect
its proper operation. Carry out
the connections according to the
dimensions and connections given
in Section 4.1.
1 The gas connection (see Section 4.1) must be carried out in
compliance with current regulations.
2 Carry out the connection with a rigid metal pipe (for the gas
supply) or a flexible pipe (of approved type, not to be con-
fused with flexible elastomer connectors) for LPG system,
with continuous s/steel wall, placing a gas valve between the
system and the water heater (AS CLOSE AS POSSIBLE TO
THE UNIT).
3 After connection, check that all gas connections are tight.
Therefore, do a tightness test and, to avoid any damage
to the unit due to overpressure, leave the gas inlet valve
closed.
Make sure the pressure and flow rate are those indicated for the
unit's consumption.
See the Technical Data table, Section 4.3.
When using the hose (approved, not to be
confused with the flexible elastomer con-
nectors) for LPG, pay particular attention
to the following:
67
EN