Electrical installation and system setup

5.1 General

Simple wiring of the entire system is provided by the pre-wired muting actuators and the connection boxes:
F39-TGR-MCL-CML:
Connector box for the transmitter side of an active/active system
eg. F3S-TGR-CL_-K2-500 + F39-TGR-MCL
F39-TGR-MCL-CMD:
Connector box for the Receiver side of an active/active system

5.2 Wiring and setup of the system

1) disconnect the power supply to the F3S-TGR-CL safety sensor system
2) Set the required muting mode in the F3S-TGR-CL safety sensor by using the DIP switches as described in
the F05 or F06 manual. Please make sure to reinstall the cover after setting the DIP-switches.
3) Connect the
a. F39-TGR-MCL-CML connection box to the transmitter in an active/active system
b. F39-TGR-MCL-CMD connection box to the receiver in an active/active system
c. F39-TGR-MCL-CMD connection box to the transceiver in an active/passive system
Remark: no wiring is needed on the passive side of an active/passive system
Remark: both F39-TGR-MCL-CM_ connection boxes can be used in T- or L- muting applications
4) Connect each muting actuator to the connection box by using the M12 connectors
5) Set the DIP-switches on the F39-TGR-MCL muting actuators for the correct sequence of the muting signals
as shown in chapter 5.3 in this manual.
6) Connect the power supply
7) Align the F3S-TGR-CL safety sensor as shown in the F05E-EN-0x or F06E-EN-0x - manual
8) Align the F39-TGR-MCL_ muting actuators as shown in chapter 5.6 in this manual.
9) Adjust the timing of the muting signals if needed.
eg. F3S-TGR-CL_-K2-500 + F39-TGR-MCL or
Transceiver side of an active/passive system
eg. F3S-TGR-CL_-K2C-500 + F39-TGR-MCL-R
11