Safety Precautions; Alert Statements In This Manual; For Users; For Installations - Omron F39-TGR-MCL Series Installation And Operation Manual

Table of Contents

Advertisement

F39-TGR-MCL_
1

Safety precautions

In order to use the F3S-TGR-CL safety sensor together with a F39-TGR-MCL_ muting actuator, the precautions
listed in this manual indicated by alert symbols and descriptions must be followed in addition to the precautions
listed in the manual of the F3S-TGR-CL safety sensor. Failure to follow all precautions and alerts may result in an
unsafe use or operation. For additional information, please refer to the:
- F05E-EN-0x Installation and operation manual for F3S-TGR-CL Finger- and hand protection sensors
- F06E-EN-0x Installation and operation manual for F3S-TGR-CL Body protection sensors
- F07E-EN-0x Precautions for F3S-TGR-CL safety sensor range
The following indications and symbols are used for the application:
WARNING This sign indicates a potentially hazardous situation which, if not avoided, will result in minor
or moderate injury, or may result in serious injury or death. Additionally there may be significant property
damage.
2

Alert statements in this manual

The alert statements shown in this manual are specific for the F39-TGR-MCL_ muting actuators. Refer to the
installation and operation manual of the safety sensor for alert statements that are specific for the safety sensor.

2.1 For users

WARNING When changes are made to each function using the selector switches, the administrator must
manage the detail of the changes and perform the changes. Accidental functional setting change may
result in a serious injury.

2.2 For installations

WARNING After unpacking and before installing the F39-TGR-MCL_ system please check the
mechanical condition of the system carefully. Do not install a mechanically damaged product. Return this
to your OMRON service for inspection or repair. Failure to do so may result in serious injury.
WARNING Do not drop the products. Dropping the products may lead to internal or external damage.
Please return a F39-TGR-MCL_ system that was dropped on the floor to your OMRON service for
inspection or repair. Failure to do so may result in serious injury.
WARNING Make sure to test the operation of the F39-TGR-MCL_ system after installation to verify that
the F39-TGR-MCL_ system operates as intended. Make sure to stop the machine until the test is
complete. Unintended function settings may cause a person to go undetected, resulting in serious injury.
WARNING The muting and override functions disable the safety functions of the device. You must
ensure safety using other method when these functions are operating.
WARNING Install muting sensors so that they can distinguish between the object that is being allowed to
pass through the detection zone and a person. If the muting function is activated by the detection of a
person, it may result in serious injury.
WARNING A sufficiently trained and qualified person must properly configure muting related timings for
its specific application, and that person must have responsibility for settings, especially when the muting
time limit is infinite.
WARNING Do not place fluorescent and/or incandescent lights within the effective aperture angle of the
receiver, as it may influence the F39-TGR-MCL_ system under certain circumstances.
WARNING When using more than 1 set of F39-TGR-MCL_ system, install them so that mutual
interference does not occur.
WARNING Make sure that the F39-TGR-MCL_ system is securely mounted and its cables and
connectors are properly connected.
WARNING Make sure that foreign objects such as water, oil, or dust do not enter the inside of the F39-
TGR-MCL_ system while the cover for the selector switches is open and tighten the screws of the cover
firmly after changing the settings.
6

Advertisement

Table of Contents
loading

Table of Contents