Port alias
Setting
1 to 15 characters
(E.g., PLC-No.1)
"Port alias" is included to allow easy identification of the serial devices that are connected to
NPort 5200's serial port.
Serial Parameters
Check the serial communication parameters in your Serial Device's user's manual. You should set
up NPort 5200's serial parameters with the same communication parameters used by your serial
devices.
Baud rate
Setting
50 bps to 115.2 Kbps
Data bits
Setting
5, 6, 7, 8
When the user sets Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits.
Stop bits
Setting
1, 2
Stop bits will be set to 1.5 when Data bits is set to 5 bits.
Parity
Setting
None, Even, Odd, Space, Mark
Flow control
Setting
None, RTS/CTS, DTR/DSR, Xon/Xoff
Web Console Configuration
Factory Default
None
Factory Default
115.2 Kbps
Factory Default
8
Factory Default
1
Factory Default
None
Factory Default
RTS/CTS
NPort 5200 Series User's Manual
Necessity
Optional
Necessity
Required
Necessity
Required
Necessity
Required
Necessity
Required
Necessity
Required