5200 Series
User's Manual
Fourth Edition, May 2004

Advertisement

Table of Contents
loading

Summary of Contents for Moxa Technologies NPort 5200 Series

  • Page 1 5200 Series User’s Manual Fourth Edition, May 2004...
  • Page 2 Information provided in this manual is intended to be accurate and reliable. However, Moxa Technologies assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.
  • Page 4: Table Of Contents

    Getting Started .................2-1 Panel Layout ..................2-2 Connecting the Hardware ..............2-3 Wiring Requirements ................2-3 Connecting the Power................2-3 Grounding NPort 5200 Series..............2-4 Connecting to the Network ............... 2-4 Connecting to a Serial Device..............2-4 LED Indicators..................2-4 Chapter 3 Initial IP Address Configuration .............3-1...
  • Page 5 Export/Import.................... 6-9 Monitor ....................6-9 Port Monitor..................6-12 COM Mapping ..................6-13 On-line COM Mapping................6-13 Off-line COM Mapping ................6-16 IP Location ................... 6-16 Chapter 7 IP Serial LIB ..................7-1 Overview ....................7-2 IP Serial LIB Function Groups..............7-3 Example Program ..................
  • Page 7: Chapter 1 Introduction

    Introduction Chapter 1 Welcome to the NPort 5200 Series of advanced serial device servers that make it easy to network enable your serial devices. The NPort 5200 Series consists of 4 models: NPort 5210 (2 ports for RS-232), NPort 5230 (1 port for RS-232; 1 port for RS-422/485), NPort 5232 (2 ports for RS-422/485), and NPort 5232I (2 ports for RS/422/485, with isolation).
  • Page 8: Overview

    API (Winsock or BSD Sockets) by providing TCP Server Mode, TCP Client Mode, and UDP Mode. And thanks to NPort 5200 Series’ Real COM/TTY drivers, software that works with COM/TTY ports can be set up to work over a TCP/IP network in no time. This excellent feature preserves your software investment and lets you enjoy the benefits of networking your serial devices instantly.
  • Page 9: Product Specifications

    Serial Communication Parameters Parity None, Even, Odd, Space, Mark Data Bits 5, 6, 7, 8 Stop Bit 1, 1.5, 2 Flow Control RTS/CTS (only for RS-232 port), XON/XOFF Transmission Speed 50 bps to 115.2 Kbps NPort 5200 Series User’s Manual...
  • Page 10 0 to 55°C (32 to 131°F), 5 to 95%RH Storage Temperature -40 to 85°C (-4 to 185°F), 5 to 95%RH Regulatory Approvals FCC Class A, CE Class A Safety UL, CUL, TÜV WARRANTY 5 years NPort 5200 Series User’s Manual...
  • Page 11: Chapter 2 Getting Started

    Chapter 2 This chapter includes information about installing NPort 5200. The following topics are covered: Panel Layout Connecting the Hardware Wiring Requirements Connecting the Power Grounding NPort 5200 Series Connecting to the Network Connecting to a Serial Device LED Indicators...
  • Page 12: Panel Layout

    Panel Layout NPort 5230 NPort 5210 NPort 5232I NPort 5232 NPort 5200 Series User’s Manual...
  • Page 13: Connecting The Hardware

    Getting Started Connecting the Hardware This section describes how to connect NPort 5200 Series to serial devices for first time testing purposes. We cover Wiring Requirements, Connecting the Power, Grounding NPort 5200 Series, Connecting to the Network, Connecting to a Serial Device, and LED Indicators.
  • Page 14: Grounding Nport 5200 Series

    NPort 5210. Refer to Chapter 1 under Optional Accessories for information on the RJ45-to-DB25 and RJ45-to-DB9 cables. LED Indicators The top panels of NPort 5200 Series have four LED indicators, as described in the following table. LED Name...
  • Page 15: Initial Ip Address Configuration

    Initial IP Address Configuration Chapter 3 When setting up your NPort 5200 for the first time, the first thing you should do is configure the IP address. This chapter introduces the method to configure the device server’s IP address. Select one of the initial IP Address configuration methods to configure NPort 5200’s IP Address.
  • Page 16: Initializing Nport 5200'S Ip Address

    NPort 5200s. See Chapter 5 for details on how to install NPort 5200 Administration Suite, and how to use this suite of useful utilities to set up IP addresses and configure your NPort 5200 Series serial device servers.
  • Page 17: Telnet Console

    3. When the Telnet window opens, if you are prompted to input the Console password, input the password and then press Enter. Note that this page will only appear if the NPort 5200 is password protected. NPort 5200 Series User’s Manual...
  • Page 18 5. Type 1 to select IP address and then press Enter. 6. Use the Backspace key to erase the current IP address, type in the new IP address, and then press Enter. 7. Press any key to continue. NPort 5200 Series User’s Manual...
  • Page 19: Serial Console (19200, N, 8, 1)

    2. From the Windows desktop click on Start Programs PComm Lite Terminal Emulator. 3. When the PComm Terminal Emulator window opens, first click on the Port Manager menu item and select Open, or simply click on the Open icon. NPort 5200 Series User’s Manual...
  • Page 20 NPort 5200 has been set up for password protection. 9. Start configuring the IP address under Network Settings. Refer to step 4 in the Telnet Console section for the rest of the IP settings. NPort 5200 Series User’s Manual...
  • Page 21: Choosing The Proper Operation Mode

    Choosing the Proper Operation Mode Chapter 4 In this section, we describe the various NPort 5200 operation modes. The options include an operation mode that uses a driver installed on the host computer, and operation modes that rely on TCP/IP socket programming concepts. After choosing the proper operation mode in this chapter, refer to Chapter 5 for detailed configuration parameter definitions.
  • Page 22: Overview

    1. The host requests a connection from the NPort 5200 configured for TCP Server Mode. 2. Once the connection is established, data can be transmitted in both directions—from the host to the NPort 5200, and from the NPort 5200 to the host. NPort 5200 Series User’s Manual...
  • Page 23: Tcp Client Mode

    NPort 5200 Series User’s Manual...
  • Page 24: Real Com Mode

    Real COM Mode allows several hosts to have access control of the same NPort 5200. The driver that comes with your NPort 5200 controls host access to attached serial devices by checking the host’s IP address. Refer to Accessible IP Settings in Chapter 5 for more details. NPort 5200 Series User’s Manual...
  • Page 25: Web Console Configuration

    Web Console Configuration Chapter 5 The Web Console is the most user-friendly method available to configure NPort 5200 Series. This chapter introduces the Web Console function groups and function definitions. Opening Your Browser Basic Settings Network Settings Serial Settings Operation Mode Settings...
  • Page 26: Opening Your Browser

    NPort 5200 uses cookies only for “password” transmission. Refer to Chapter 3, “Initial IP Address Configuration,” to see how to configure the IP address. Examples shown in this chapter use the Factory Default IP address (192.168.127.254). NPort 5200 Series User’s Manual...
  • Page 27 If your NPort 5200 application requires using password protection, you must enable the cookie function in your browser. If the cookie function is disabled, you will not be allowed to enter the Web Console Screen. NPort 5200 Series User’s Manual...
  • Page 28: Basic Settings

    GMT (Greenwich Mean Time) Optional Local time Setting Factory Default Necessity User adjustable time GMT (Greenwich Mean Time) Optional (1900/1/1-2037/12/31) Click on the Modify button to open the Modify time settings window to input the correct local time. NPort 5200 Series User’s Manual...
  • Page 29: Network Settings

    The IP address must be unique within the network (otherwise, NPort 5200 will not have a valid connection to the network). First time users can refer to Chapter 3, “Initial IP Address Configuration,” for more information. NPort 5200 Series User’s Manual...
  • Page 30 DHCP or BOOTP server. The Timeout for each try increases from 1 second, to 3 seconds, to 5 seconds. If the DHCP/BOOTP Server is unavailable, the firmware will use the default IP address (192.168.127.254), Netmask, and Gateway for IP settings. NPort 5200 Series User’s Manual...
  • Page 31 NPort 5200 is physically located. IP Address Report When NPort 5200 Series products are used in a dynamic IP environment, users must spend more time with IP management tasks. For example, if NPort 5200 works as a server (TCP or UDP), then the host, which acts as a client, must know the IP address of the server.
  • Page 32: Serial Settings

    Click on Serial Settings, located under Main Menu, to display serial port settings for ports 1 and To modify serial settings for a particular port, click on either Port 1 or Port 2 under Serial Settings, located under Main Menu on the left side of the browser window. NPort 5200 Series User’s Manual...
  • Page 33 Stop bits will be set to 1.5 when Data bits is set to 5 bits. Parity Setting Factory Default Necessity None, Even, Odd, Space, Mark None Required Flow control Setting Factory Default Necessity None, RTS/CTS, DTR/DSR, Xon/Xoff RTS/CTS Required NPort 5200 Series User’s Manual...
  • Page 34 NPort 5200’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. To prevent data loss during communication, disable the FIFO setting when your serial device does not have a FIFO. 5-10 NPort 5200 Series User’s Manual...
  • Page 35: Operating Settings

    1 and 2 4-wire RS-485 Required 2-wire RS-485, 5232I 4-wire RS-485 Operating Settings Click on Operating Settings, located under Main Menu, to display the operating settings for both of NPort 5200’s serial ports. Real COM Mode NPort 5200 Series User’s Manual 5-11...
  • Page 36 Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly. 5-12 NPort 5200 Series User’s Manual...
  • Page 37: Tcp Server Mode

    1 to 99 min: NPort 5200 automatically closes the TCP connection if there is no TCP activity for the given time. After the connection is closed, NPort 5200 starts listening for another host’s TCP connection. NPort 5200 Series User’s Manual 5-13...
  • Page 38 Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly. 5-14 NPort 5200 Series User’s Manual...
  • Page 39 TCP port conflict with other applications, the user can set the Command port to another port if needed. IP-Serial Lib will automatically check the Command Port on NPort 5200 so that the user does not need to configure the program. NPort 5200 Series User’s Manual 5-15...
  • Page 40: Tcp Client Mode

    The Inactivity time should at least be set larger than that of Force transmit timeout. To prevent the unintended loss of data due to the session being disconnected, it is highly recommended that this value is set large enough so that the intended data transfer is completed. 5-16 NPort 5200 Series User’s Manual...
  • Page 41 Destination IP address 1 Setting Factory Default Necessity IP address or Domain Name None Required (E.g., 192.168.1.1) Allows NPort 5200 to connect actively to the remote host whose IP address is set by this parameter. NPort 5200 Series User’s Manual 5-17...
  • Page 42: Udp Mode

    Start up: Attempts to establish a TCP connection as soon as the NPort 5200 is powered on. Any Character: Attempts to establish a TCP connection as soon as the NPort 5200 starts receiving serial data. UDP Mode 5-18 NPort 5200 Series User’s Manual...
  • Page 43 The serial communication buffer size for NPort 5200 is 1 KB per port. Destination IP address 1 Setting Factory Default Necessity IP address range Begin: Empty Required E.g., Begin: 192.168.1.1 End: Empty End: 192.168.1.10 Port: 4001 NPort 5200 Series User’s Manual 5-19...
  • Page 44: Accessible Ip Settings

    Hosts on a specific subnet can access the NPort 5200 Enter “IP address/255.255.255.0” (e.g., “192.168.1.0/255.255.255.0”). Any host can access the NPort 5200 Disable this function by un-checking the “Enable the accessible IP list” checkbox. Refer to 5-20 NPort 5200 Series User’s Manual...
  • Page 45: Auto Warning Settings

    Factory Default Necessity 1 to 15 characters None Optional From E-mail address Setting Factory Default Necessity 1 to 63 characters None Optional E-mail address 1/2/3/4 Setting Factory Default Necessity 1 to 63 characters None Optional NPort 5200 Series User’s Manual 5-21...
  • Page 46: Event Type

    NPort 5200 reboots. If the NPort 5200 is unable to send an e-mail message to the mail server within 15 seconds, NPort 5200 will reboot anyway, and abort the e-mail auto warning. 5-22 NPort 5200 Series User’s Manual...
  • Page 47 NPort 5210, and port 1 for NPort 5230). Since NPort 5232 and NPort 5232I do not have RS-232 interface, the DCD changed and DSR changed options will not appear in the Event Type screen. NPort 5200 Series User’s Manual 5-23...
  • Page 48: Change Password

    By using the Import function of Windows Administrator, your configuration can be re-loaded into NPort 5200 after using “Load Factory Default.” Refer to Chapter 6 for more details about the Export and Import function. 5-24 NPort 5200 Series User’s Manual...
  • Page 49: Load Factory Default

    Web Console Configuration Load Factory Default This function will reset all of NPort 5200’s settings to the factory default values. Be aware that previous settings will be lost. NPort 5200 Series User’s Manual 5-25...
  • Page 51: Configuring Windows Administrator

    Configuring Windows Administrator Chapter 6 The following topics are covered in this chapter: Overview Installing Windows Administrator Configuration Broadcast Search Unlock Password Protection Configuring NPort 5200 Upgrade Firmware Export/Import Monitor Port Monitor COM Mapping On-line COM Mapping Off-line COM Mapping IP Location...
  • Page 52: Overview

    Administrator and the IP Serial Library, and provides everything you need to remotely manage, monitor, and modify your NPort 5200s—hassle free. Device Server Administrator ONLY supports NPort 5200 Series products. Installing Windows Administrator 1. Once the Setup program starts running, click on Yes to proceed.
  • Page 53 5. Click on Install to proceed with the installation. 6. The Installing window reports the progress of the installation. 7. Click on Next to proceed with the installation. 8. Click on Finish to complete the installation of NPort 5200 Administration Suite. NPort 5200 Series User’s Manual...
  • Page 54: Configuration

    Since the Broadcast Search function searches by MAC address and not IP address, all NPort 5200s connected to the LAN will be located, regardless of whether or not they are part of the same subnet as the host. NPort 5200 Series User’s Manual...
  • Page 55: Unlock Password Protection

    Address to locate NPort 5200s connected to the LAN. Unlock Password Protection If the NPort 5200 is password protected, then you will not be able to use the right click method to open the configuration page. NPort 5200 Series User’s Manual...
  • Page 56 The NPort 5200 is not password protected, and “Search by IP address” was used to locate it. Lock Fixed The NPort 5200 is password protected, “Specify by IP address” was used to locate it, and the password has not yet been entered from within the current Administrator session. NPort 5200 Series User’s Manual...
  • Page 57: Configuring Nport 5200

    You can simultaneously modify the configurations of multiple NPort 5200s that are of the same model. To select multiple NPort 5200s, hold down the Ctrl key when selecting additional NPort 5200s, or hold down the Shift key to select a group of NPort 5200s. NPort 5200 Series User’s Manual...
  • Page 58: Upgrade Firmware

    You can simultaneously upgrade the firmware of multiple NPort 5200s that are of the same model. To select multiple NPort 5200s, hold down the Ctrl key when selecting an additional NPort 5200, or hold down the Shift key to select a block of NPort 5200s. NPort 5200 Series User’s Manual...
  • Page 59: Export/Import

    1. First use Broadcast Search under the Configuration Function group, and then click on Monitor Add Target Select target from the list. 2. First click on Monitor, and then Add Target Rescan. Select Broadcast under the Configuration menu bar item. Click on Monitor. NPort 5200 Series User’s Manual...
  • Page 60 Use the single arrowhead buttons to move highlighted items from one box to the other. Use the double arrowhead buttons to move all items in one box to the other. Select a Refresh Rate (the default is 3 seconds). 6-10 NPort 5200 Series User’s Manual...
  • Page 61 If the NPort 5200 gets reconnected, a warning will be displayed to remind the user that the NPort 5200 is now “Alive.” The NPort 5200 that was reconnected, and is now “Alive,” will be shown in black color. NPort 5200 Series User’s Manual 6-11...
  • Page 62: Port Monitor

    Select or de-select Monitor Items. Use the single arrowhead buttons to move highlighted items from one box to the other. Use the double arrowhead buttons to move all items in one box to the other. 6-12 NPort 5200 Series User’s Manual...
  • Page 63: Com Mapping

    Add the target to which you would like to map COM ports. The NPort 5200 list that appears is the list generated by the previous Broadcast Search. Select the NPort 5200 to which you would like to map COM ports. NPort 5200 Series User’s Manual 6-13...
  • Page 64 Tx FIFO becomes empty; and an Rx interrupt will be generated for each incoming byte. This will result in a faster response and lower throughput. If you want to use XON/XOFF flow control, we recommend setting FIFO to Disable. 6-14 NPort 5200 Series User’s Manual...
  • Page 65 The host computer will not have the ability to use the COM port until after Apply Change is selected. Select Discard Change to tell Administrator NOT to save the COM Mapping information to the host. NPort 5200 Series User’s Manual 6-15...
  • Page 66: Off-Line Com Mapping

    When NPort 5200 is used in a dynamic IP environment, users must spend more time with IP management tasks. NPort 5200 Series products help out by periodically reporting their IP address to the IP location server, in case the dynamic IP has changed.
  • Page 67 Then configure the Local Listen Port to be the same as the NPort 5200’s “Auto report to UDP port” setting. Click Go to start receiving the Auto IP address report from the NPort 5200. NPort 5200 Series User’s Manual 6-17...
  • Page 68 6-18 NPort 5200 Series User’s Manual...
  • Page 69: Ip Serial Lib

    IP Serial LIB Chapter 7 The following topics are covered in this chapter: Overview IP Serial LIB Function Groups Example Program...
  • Page 70: Overview

    How to install IP Serial Library IP Serial Lib comes with the NPort 5200 Administration Suite. Refer to the IPSerial directory for more detail about the function definitions. NPort 5200 Series User’s Manual...
  • Page 71: Ip Serial Lib Function Groups

    /* wait for 1000 ms for data */ nsio_read(port, buffer, 200); /* read 200 bytes from port 1 */ nsio_close(portid); /* close this serial port */ nsio_end(); /* close IP Serial Library */ NPort 5200 Series User’s Manual 7-3...
  • Page 72 NPort 5200 Series User’s Manual...
  • Page 73: Appendix A Pinouts And Cable Wiring

    Pinouts and Cable Wiring Appendix A In this appendix, we cover the following topics. Port Pinout Diagrams Ethernet Port Pinouts Serial Port Pinouts Cable Wiring Diagrams Ethernet Cables Serial Cables...
  • Page 74: Port Pinout Diagrams

    Port Pinout Diagrams Ethernet Port Pinouts Serial Port Pinouts 8-pin RJ45 RS-232 Port Pinouts for NPort 5210 Terminal Block RS-232 & RS-422/485 Pinouts for NPort 5230 NPort 5200 Series User’s Manual...
  • Page 75: Cable Wiring Diagrams

    Pinouts and Cable Wiring Cable Wiring Diagrams Ethernet Cables Serial Cables 8-pin RJ45 to DB25 Female for NPort 5210 (Cable Name: CBL-RJ45F25-150) NPort 5200 Series User’s Manual A-3...
  • Page 76 8-pin RJ45 to DB25 Male for NPort 5210 (Cable Name: CBL-RJ45M25-150) 8-pin RJ45 to DB9 Female for NPort 5210 (Cable Name: CBL-RJ45F9-150) 8-pin RJ45 to DB9 Male for NPort 5210 (Cable Name: CBL-RJ45M9-150) NPort 5200 Series User’s Manual...
  • Page 77: Appendix B Well Known Port Numbers

    Well Known Port Numbers Appendix B In this appendix, which is included for your reference, we provide a list of Well Known port numbers that may cause network problems if you set NPort 5200 to one of these ports. Refer to RFC 1700 for Well Known port numbers, or refer to the following introduction from the IANA.
  • Page 78 Finger Protocol World Wide Web HTTP Remote Telnet Service Sun Remote Procedure Call (Sunrpc) Network news Tcanster Protocol (NNTP) Network Time protocol (nnp) SNMP (Simple Network Mail Protocol) SNMP Traps IPX (Used for IP Tunneling) NPort 5200 Series User’s Manual...
  • Page 79 SNMP Agents with MIB II & RS-232 Appendix C like groups NPort 5200 has built-in SNMP (Simple Network Management Protocol) agent software that supports SNMP Trap, RFC1317 RS-232 like groups and RFC 1213 MIB-II. The following table lists the standard MIB-II groups, as well as the variable implementation for NPort 5200. RFC1213 MIB-II supported SNMP variables: System MIB Interfaces MIB...
  • Page 80 SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRtoMin snmpOutPkts UdpInErrors tcpRtoMax snmpInBadVersions UdpOutDatagrams tcpMaxConn snmpInBadCommunityNames UdpLocalAddress tcpActiveOpens snmpInASNParseErrs UdpLocalPort tcpPassiveOpens snmpInTooBigs tcpAttempFails snmpInNoSuchNames Address Translation MIB tcpEstabResets snmpInBadValues AtIfIndex tcpCurrEstab snmpInReadOnlys AtPhysAddress tcpInSegs snmpInGenErrs AtNetAddress tcpOutSegs snmpInTotalReqVars NPort 5200 Series User’s Manual...
  • Page 81 Port Group rs232Number rs232PortTable rs232AsyncPortTable rs232PortEntry rs232AsyncPortEntry rs232PortIndex rs232AsyncPortIndex rs232PortType rs232AsyncPortBits rs232PortInSigNumber rs232AsyncPortStopBits rs232PortOutSigNumber rs232AsyncPortParity rs232PortInSpeed rs232PortOutSpeed The Input Signal Table The Output Signal Table rs232InSigTable rs232OutSigTable rs232InSigEntry rs232OutSigEntry rs232InSigPortIndex rs232OutSigPortIndex rs232InSigName rs232OutSigName rs232InSigState rs232OutSigState NPort 5200 Series User’s Manual C-3...
  • Page 82 NPort 5200 Series User’s Manual...
  • Page 83: Appendix D Service Information

    Service Information Appendix D This appendix shows you how to contact Moxa for information about this and other products, and how to report problems. In this appendix, we cover the following topics. MOXA Internet Services Problem Report Form Product Return Procedure Revision History...
  • Page 84: Moxa Internet Services

    Moxa Internet Services has been set up to provide technical support, driver updates, product information, and user’s manual updates. The following services are provided E-mail for technical support ....... support@moxa.com.tw World Wide Web (WWW) Site for product information: ......http://www.moxa.com ......http://www.moxa.com.tw NPort 5200 Series User’s Manual...
  • Page 85: Problem Report Form

    Service Information Problem Report Form MOXA NPort 5200 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product: NPort 5210 NPort 5230 NPort 5232 NPort 5232I 2. Serial Number: _________________ Problem Description: Please describe the symptoms of the problem as clearly as possible, including any error messages you see.
  • Page 86: Product Return Procedure

    Carefully pack the product in an anti-static package, and send it, pre-paid, to the dealer. The PRA should be visible on the outside of the package, and include a description of the problem, along with the return address and telephone number of a technical contact. NPort 5200 Series User’s Manual...
  • Page 87: Revision History

    Service Information Revision History Document Edition Revision Date Revision Details August 25, 2003 1. Updated the edition of this manual on the title page. 2. Updated the Moxa Email and phone number on the title page. 3. p.2-4 Changed “Link” to “Ethernet” under “Connecting to the Network”.
  • Page 88 6. p. 6-17 Changed “TCP” to “UDP”. 7. Added Appendix E. NPort 5200 Series User’s Manual...
  • Page 89: Appendix E Auto Ip Report Protocol

    Auto IP Report Protocol Appendix E NPort Series provides several ways to configure Ethernet IP addresses. One of them is DHCP Client. When you set up the NPort to use DHCP Client to configure Ethernet IP addresses, it will automatically send a DHCP request over the Ethernet to find the DHCP Server. And then the DHCP Server will send an available IP address to the NPort.
  • Page 90 0x1534 NPort 5430I 0x80000312 0x0312 NPort 5230 0x80000312 0x0322 NPort 5210 0x80000312 0x0332 NPort 5232 0x80000312 0x1332 NPort 5232I 0x80005610 0x5618 NPort 5610-8 0x80005610 0x5613 NPort 5610-16 0x80005610 0x5638 NPort 5630-8 0x80005610 0x5633 NPort 5630-16 NPort 5200 Series User’s Manual...

Table of Contents