Maintenance
10.2

Cleaning

Cleaning the dirt trap
The dirt trap in the degassing line must be cleaned no later than after the expiry of the continuous
degassing time. Check the dirt traps after every filling process or extended operation.
1.
Press 'Stop' on the control panel of the controller.
The device is non-functioning and the vacuum pump is shut down.
2.
Close the ball valve (1) upstream of the dirt trap (2).
3.
Slowly unscrew the cap with the strainer.
The residual pressure in the pipe segment is released.
4.
Pull the strainer out of the cap.
5.
Clean the strainer with a soft brush and rinse it with clear water.
6.
Check the seal for damage and replace as necessary.
7.
Insert the sieve in the cap and turn the cap with the sieve in the housing of the dirt trap (2).
8.
Open the ball valve (1) upstream of the dirt trap (2).
9.
Press 'Auto' on the control panel of the controller.
The device is switched on and the vacuum pump is in operation.
24 — English