8
Operation
8.1
Automatic mode
Automatic mode includes the two operating modes continuous degassing and interval degassing.
Note!
The starting time of the degassing processes is specified based on the time at the very first
start.
To reset and for new setting of the start time, see chapter 9.3 "Reset" on page 22 .
Continuous degassing
This mode is started during first commissioning by pressing the Auto button. Multiple degassing
cycles without pause times are carried out over a fixed period of several hours during the day. The
daily start time is set based on the time of the initial commissioning.
Interval degassing
This mode comprises repeating intervals. There is a pause time between the intervals. Once
continuous degassing has completed, interval degassing starts automatically.
8.2
Stop mode
On the controller, press 'Stop' to activate stop mode. The Auto LED of the control panel goes out, the
Stop LED lights up.
Except for the display of information, the device is non-functional in Stop mode. Function monitoring
is stopped. The vacuum pump is switched off.
Note!
The system triggers an error message if Stop mode is activated for more than 4 hours.
8.3
Restarting
Note!
Recommissioning after a long shut-down takes place by pressing the 'Auto' button.