Siegenia AEROVITAL ambience smart DM Original Operating Instructions

Siegenia AEROVITAL ambience smart DM Original Operating Instructions

Ventilation unit with sound absorption for installation under the ceiling.

Advertisement

Quick Links

ORIGINAL OPERATING
INSTRUCTIONS
AERO
AEROVITAL ambience smart DM
Ventilation unit with sound absorption for installation under the ceiling.
Window systems
Door systems
Comfort systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEROVITAL ambience smart DM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siegenia AEROVITAL ambience smart DM

  • Page 1 ORIGINAL OPERATING INSTRUCTIONS AERO AEROVITAL ambience smart DM Ventilation unit with sound absorption for installation under the ceiling. Window systems Door systems Comfort systems...
  • Page 3: Table Of Contents

    10.2.4 Silent mode............10 SCOPE OF DELIVERY ........6 10.2.5 Timer ..............10 10.2.6. Warning.(replace.filter) ........10 AEROVITAL ambience smart DM ....6 10.2.7 Room temperature and air humidity ....10 5.2. Assembly.set.for.ceiling.installation ....6 MAINTENANCE ........11 UNIT DESCRIPTION ........7 11.1 Cleaning ............
  • Page 4: Target Group Of This Documentation

    • Comply.with.the.safety.regulations.for.operating. for.the.ventilation.of.closed.rooms.(kitchen,. electrical.equipment.and,.if.necessary,.for.ladders,. bathroom,.living.rooms.and.bedrooms). steps and work overhead or at certain heights. • The AEROVITAL ambience smart DM is not suitable • Use the unit only when it is in a technically sound for.dehumidification.(e.g..for.the.drying.of.new. condition.. buildings). • Do not modify the unit's components in any way.
  • Page 5: Safety Notes

    – If.the.mains.connection.cable.for.the.unit.is. setting. damaged,.it.must.be.replaced.by.SIEGENIA,.the. company's.customer.service.department,.or. – If the SIEGENIA WLAN devices are integrated in similarly.qualified.personnel.in.order.to.prevent. your.home.WLAN,.this.must.be.encrypted.for. the development of hazards. operation. – Only.a.qualified.electrician.may.perform.any. – Please.choose.secure.passwords.consisting.of. work on the 230 V AC mains power supply that is lower.case.and.capital.letters,.numbers.and.
  • Page 6: Scope Of Delivery

    Original operating instructions AERO AEROVITAL ambience smart DM Scope of delivery 5.1 AEROVITAL ambience smart DM 5.2 Assembly set for ceiling installation Item Name Quantity Item Name Quantity Storage stone Drilling template Weather grille Assembly case Pipe Plug.fixing.hole Cover.electrical.connection Insect screen AEROVITAL ambience Cable.junction.box...
  • Page 7: Unit Description

    Original operating instructions AERO AEROVITAL ambience smart DM Unit description 6.1 Unit function 6.2 Designation of parts 6.1.1 Ventilation and aeration with blower and heat recovery • The outside air (1) is drawn in and enters the room 1. On/Off.(and.brightness.sensor as.filtered.supply.air.(2).
  • Page 8: Led Indicator

    Original operating instructions AERO AEROVITAL ambience smart DM LED indicator 7.1 Operating status Operating status Calibration.of.the.sensors »AUTO«.flashes (see.calibration.of.the.air.quality.sensors,.page.9) »Blower level« Selected.blower.level.is.active lights up »AUTO« lights Automatic.mode.is.active* »WRG« lights Heat.recovery.is.active * In automatic mode, the blowers are not switched off, but continue to run at a minimum level 7.2 Special function...
  • Page 9: Commissioning

    Original operating instructions AERO AEROVITAL ambience smart DM Commissioning 8.1 Calibration of the air quality sensors 8.2 Requirements for a faultless calibration • The.sensors.are.calibrated.automatically.as.soon.as. • The.room.must.be.well.aired.before.the.calibration. the AEROVITAL ambience smart is connected to the • The room temperature must be between 5 °C and electricity grid (and also following a power failure).
  • Page 10: Operation Via Smartphone Or Tablet

    Original operating instructions AERO AEROVITAL ambience smart DM 10 Operation via smartphone or tablet The AEROVITAL ambience smart DM smart 10.2.3 Automatic mode can be controlled by smartphone or tablet and.offers.additional.device.functions.via.the. •.For.information.on.the.automatic.mode,.see.page.7. SIEGENIA Comfort app. 10.2.4 Silent mode The.silent.mode.restricts.the.blower.performance,. thus overriding all blower levels that are programmed in.other.functions.(e..g..timer)..The.silent.mode.can.
  • Page 11: Maintenance

    • Never use cleaning agents that are aggressive or contain.solvents,.or.sharp-edged.objects,.as.these. may damage the surfaces of the casing. • Never clean the unit with a high-pressure cleaner or steam-jet cleaner. • Clean the AEROVITAL ambience smart DM with a.cloth.moistened.with.a.mild.soap.solution.or. cleaning agent. 11.2 Replacing the filter Remove the casing cover •...
  • Page 12 Original operating instructions AERO AEROVITAL ambience smart DM Position.the.bottom.cover.plate.and.press.into.place WARNING Release.and.remove.the.bottom.cover.plate Strong gravitational pull of the magnets If.you.are.not.careful,.your.fingers.or.hand.could.be. caught between two plates. This could lead to crushing and bruises. • Proceed.with.caution. Remove.the.contaminated.exhaust.air.filter.(LH.and. Fix.the.bottom.cover.plate.with.fixing.brackets Insert.the.clean.exhaust.air.filter.(LH.and.RH) 12/20 04.2020 H47.WANS013EN-02...
  • Page 13 Original operating instructions AERO AEROVITAL ambience smart DM Remove.the.muffler Release.the.fixing.brackets.of.the.top.cover.plate Remove.the.contaminated.supply.air.filter Release and remove the top cover plate Insert.the.clean.air.supply.filter H47.WANS013EN-02 04.2020 13/20...
  • Page 14 Original operating instructions AERO AEROVITAL ambience smart DM Position.the.muffler.in.the.centre Fix the top cover plate Position.the.top.cover.plate.and.press.into.place WARNING Strong gravitational pull of the magnets If.you.are.not.careful,.your.fingers.or.hand.could.be. caught between two plates. This could lead to crushing and bruises. Close the casing cover • Proceed.with.caution.
  • Page 15: Accessories

    Original operating instructions AERO AEROVITAL ambience smart DM Tighten the grub screw The.filter.change.display.must.be.reset.after.changing. the.filter. This is performed either using the SIEGENIA Comfort app or by pressing the Minus and Plus.buttons.alternatively 12 Accessories Material description Material number Content 1x.supply.air.filter.M5 Filter set AEROVITAL ambience L5133000-093010 2x.exhaust.air.filter.M5...
  • Page 16: Rectification Of Malfunctions

    No.WLAN.connection.to.the. AEROVITAL ambience smart DM smart 2. All.LEDS.light.up.briefly 3. The AEROVITAL ambience smart DM smart switches to blower level 1 and has been reset to the.factory.settings. The temperature sensor is located The outside temperature in the unit interior. Depending displayed on the on.the.exterior.influences,.the.
  • Page 17: Technical Specifications

    Original operating instructions AERO AEROVITAL ambience smart DM 14 Technical specifications AEROVITAL ambience smart DM AEROVITAL ambience smart DM Level.1 L = 20 dB (A) Inherent noise Level.2 L = 22 dB (A) (measured according to DIN EN Level.3 L = 25 dB (A) ISO.3741.with.room.insulation.of.
  • Page 18: Eu Declaration Of Conformity With Regard To Ce Marking

    Original operating instructions AERO AEROVITAL ambience smart DM 15 EU Declaration of Conformity with regard to CE marking For our product AEROVITAL ambience smart DM,.we.confirm.that.the.general.safety.of.the.defined.product,.in.ac- cordance.with.Directive.2001/95/EC,.is.compliant.with.the.relevant.protection.requirements.which.are.laid.down. in.the.Council.Directives.about.electrical.and.electronic.products. The.following.listed.test.standards,.which.are.harmonised.in.the.relevant.directives,.have.been.employed.for.the. evaluation: 2014/30/EC EMC Directive EN.55014-1:2006+A1:2009+A2:2011 EN.55014-2:1997+A1:2001+A2:2008 EN.61000-3-2:2014 EN.61000-3-3:2013 2014/35/EC Low voltage directive EN.60335-1:2012+A11:2014...