Ventilation unit with sound absorption for installation under the ceiling. (20 pages)
Summary of Contents for Siegenia AERO Series
Page 1
INSTALLATION AND OPERATING INSTRUCTIONS AERO AEROTUBE DD 110 AEROTUBE DD 160 Wall-mounted ventilator with sound absorption. Window systems Door systems Comfort systems...
Content Content TARGET GROUP OF THIS OPERATION..........18 DOCUMENTATION ........3 8.1. Control.of.air.flow.(inner.panel.E28) ... 18 INTENDED USE ..........3 8.2. Control.of.air.flow.(inner.panel.E18) ... 18 IMPROPER USE ..........3 CARE AND MAINTENANCE ......19 DIMENSIONS ..........3 Cleaning ............19 9.2. Replacing.the.filter.(inner.panel.E28) ..19 FEEDBACK ON DOCUMENTATION .....3 9.3.
• Do not use the AEROTUBE in environments with 150 mm). corrosive.or.explosive.atmospheres.(dust,.vapour.or. gas). Improper use Any.use.or.application.of.this.product.that.is.not.in. of.SIEGENIA.has.not.been.obtained,.are.strictly. accordance.with.its.proper.use,.or.any.adaptation. prohibited. SIEGENIA accepts no liability whatsoever of.or.modifications.made.to.the.product.and.its. for any material losses or injury to people caused by associated.components,.for.which.the.express.consent. failure.to.comply.with.this.stipulation. Dimensions All.the.dimensions.in.this.documentation.are.specified. in millimetres (mm).
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 Installation 7.1 Installation of vent duct and weather grille variant • Remove the AEROTUBE.carefully.from.the.packaging. and do not place it on the casing or front panel. We recommend.storing.the.unit.on.a.soft.surface.(e.g.. cardboard.or.sheet).during.installation. •...
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 7.2 Installation of ventilation pipe and vent duct EPP ATTENTION Sharp edges on the weather grille and perforated grid There.is.a.risk.of.injury.from.sharp.edges • Wear.protective.gloves • Remove the AEROTUBE.carefully.from.the.packaging. and do not place it on the casing or front panel. We recommend.storing.the.unit.on.a.soft.surface.(e.g..
Page 10
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 Insert pipe in the wall Seal pipe Inside.=.airtight.seal Outside = free-air seal Insulate pipe (according to requirement) 10/24 09.2019 H47.WANS010EN-04...
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 7.3 Installation of wind pressure barrier Push wind pressure barrier into the middle of the ventilation.pipe 7.4 Installation of the inner panel E28 H47.WANS010EN-04 09.2019 15/24...
Page 16
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 90° Push.the.filter.into.the.casing.as.far.as.the.wall The cable outlet in the inner panel must be on the slider side. 16/24 09.2019 H47.WANS010EN-04...
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 Operation 8.1 Control of air flow (inner panel E28) 8.2 Control of air flow (inner panel E18) Open sliders Tilt.position Close sliders Parallel-action.gap Close 18/24 09.2019 H47.WANS010EN-04...
• Never clean the unit with a high-pressure cleaner or steam-jet cleaner. • Clean AEROTUBE with a cloth moistened with a mild soap.solution.or.cleaning.agent. • The.filter.should.be.replaced.every.12.months,.at.the. latest (according to equipment). • Only.use.the.original.filters.from.SIEGENIA..You.can. purchase.replacement.filters.from.SIEGENIA.or.from. specialist retailers (see accessories page 4). 9.2 Replacing the filter (inner panel E28) Push.the.new.filter.into.the.casing.as.far.as.the.wall Remove.the.dirty.filter.from.the.casing.and.dispose.of.
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 10 Technical specifications 10.1 AEROTUBE DD 110 AEROTUBE DD 110 Weather grille PVC weather grille Inner panel Tilt.gap.7,5.mm Tilt gap 15 mm at 2 Pa at 4 Pa 11 m at 5 Pa 11 m...
Installation and operating instructions AERO AEROTUBE DD 110 / AEROTUBE DD 160 10.2 AEROTUBE DD 160 AEROTUBE DD 160 Weather grille Stainless steel weather grille hood Inner panel 7,5.mm.Parallel-action.gap open at 2 Pa 13 m at 4 Pa 12 m 20 m at 5 Pa 14 m...
Need help?
Do you have a question about the AERO Series and is the answer not in the manual?