AEROMAT VT Original operating instructions 1. Target group of this documentation • This documentation is intended for use by specialists and end users. • All instructions concerning assembly, installation and repairs described in this document are to be performed exclusively by experienced professionals with training and practice in the installation, commissioning, servicing and maintenance of decentralised ventilation units.
• Any use or application of this product that is not in accordance with its proper use, or any adaptation of or modifications made to the product and its associated components, for which the express consent of SIEGENIA has not been obtained, are strictly prohibited.
- Work on a 230 V AC mains power supply may only be performed by a qualified electrician. - If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, the company's customer service department, or similarly qualified personnel in order to prevent personal injury or damage to property.
SIEGENIA Comfort App* Operation via SIEGENIA Comfort app — — — — Optional electrical locking slider * The quick start instructions for the SIEGENIA Comfort app are located behind the front panel (To open the front panel, see page 18). 10.2018...
AEROMAT VT Original operating instructions 6. Installation 6.1 Prerequisites for installation • The position from which the outdoor air is drawn in must be selected so that any nearby emission sources have as little impact as possible on the quality of the air being drawn in. •...
Page 9
Original operating instructions AEROMAT VT 6.3 Installation sequence 1. Remove the AEROMAT VT carefully from the packaging and do not place it on the weather grille or front panel. We recommend storing the unit on a soft surface (e.g. cardboard or sheet) during installation. 2.
Page 10
› Screw on the mounting bracket in the area indicated (marker tape) or fasten it to the casing profiles with a rivet. We recommend that you use SIEGENIA aluminium mounting angles. AEROMAT VT with 911 CW weather grille AEROMAT VT with 911 HW weather grille...
Original operating instructions AEROMAT VT 7. Mains supply Depending on the design, the AEROMAT VT is connected to a suitable socket of the 230-V AC mains power supply using the Euro plug or directly to the 230-V AC mains power supply using an external switch. 7.1 Socket connection Important: When installed in damp locations, the socket for the AEROMAT VT must be installed in at least protection class 3.
Page 12
AEROMAT VT Original operating instructions 7.3 Type DS wiring scheme with external switch and internal electrical closer Cable no. Colour Black Blue Brown Transformer Flat ribbon cable 20 V∼ 20 V∼ Black Inputs Yellow Black Yellow Supply air + Supply air ― Exhaust air + Exhaust air ―...
Original operating instructions AEROMAT VT 8. Unit function 8.1 Operation by pressure differential: (DS/DSg type) • The room is ventilated through compensation of the indoor and outdoor air pressures (pressure differential). As this happens, the air normally flows into the room from outside. •...
AEROMAT VT Original operating instructions 10. Operation 10.1 Ventilation without fans (type DS/DSg and RS1) 1. Open sliders* 10.2 Ventilation with fans (type RS1) Note: Depending on the design, the membrane key is positioned on either the left or right in the AEROMAT VT. If it is on the right, the membrane key is turned 180°...
Page 15
Recommendation: use a 3-stage rotary switch provided onsite. Blower level 0 Blower level 1 Blower level 2 (Power level) Series switch Recommendation: use the SIEGENIA type VT series switch (material number: 131322) Blower level 0 Blower level 1 Blower level 2 -to- -Au-...
Page 16
AEROMAT VT Original operating instructions 10.3 Operation via smartphone or tablet (AEROMAT VT smart only) AEROMAT VT smart can be controlled via tablet or smartphone and offers additional device functions via the SIEGENIA Comfort app. 11.3.1 Teaching in the device Please follow the enclosed quick start instructions (H47.MOTS005EN) to integrate the device in your home WIFI.
Every 12 months or when the filter Depending on the level of soiling change notification illuminates 1) M5 filters must replaced not cleaned. Only use genuine filters from SIEGENIA. You can purchase replacement filters from SIEGENIA or from specialist retailers. 10.2018...
Page 18
AEROMAT VT Original operating instructions 11.3 Replacing the air canal and the filter (optional) 11.3.1 Removing the front panel The figure below shows the opening direction for a AEROMAT VT that has been installed horizontally.Note: The number and position of the components can deviate from the figure. Be sure to note the arrangement of the internal parts for special models that do not correspond to the illustration.
Page 19
Original operating instructions AEROMAT VT 11.3.3 AEROMAT VT (Type DS and RS1) 1. Pull out the mains plug or switch off the safety device for the power supply cable 2. Remove the front panel (see also "Removing the front panel" page 18) 3.
In case of a malfunction, do not open the device or try to repair it under any circumstances. If the problem is not listed in the table below, please contact your installation firm or SIEGENIA directly: Tel. +49 271 3931-0...
Original operating instructions AEROMAT VT 13. Technical specifications The values can vary according to the specific equipment configuration. AEROMAT VT RS1 / RS smart Sound absorption = 33‒49 dB = 49 dB = 49 dB = 50 dB w-1.9 w-1.9 w-1.9 w-1.9 (at 300 mm installation depth)
AEROMAT VT Original operating instructions 13.2 Information requirements (in accordance with EU Regulation 1253/2014) a Manufacturer SIEGENIA b Model identification AEROMAT VT RS1 c Energy consumption (SEV); 1.1 kWh/(m² · a); F Energy efficiency class (SEV class) ‒8.7 kWh/(m² · a); F (according to climatic zone warm / average / cold) ‒22.1 kWh/(m²...
EN 50581:2012 Technical documentation on the evaluation of electrical and electronic devices with reference to the restriction of hazardous substances This declaration is responsible for the manufacturers / importers based in the European Union submitted by: SIEGENIA-AUBI KG Hardware and ventilation technology Duisburger Straße 8...
Page 24
Phone: + Industriestraße Telefax: + Wilnsdorf info@sie enia.com GERMANY www.sie enia.com Hun ary Phone: + SIEGENIA worldwide: Austria Phone: + Italy Phone: + Belarus Phone: + Poland Phone: + Benelux Phone: + Russia Phone: + China Phone: + South Korea Phone: +...