Original operating instructions AEROVITAL Contents Target group of this documentation ..............................4 Correct use ...................................... 4 Safety notes ..................................... 5 Scope of delivery .................................... 5 Installation ....................................... 6 Unit description .....................................12 Function ......................................14 Commissioning ....................................15 Operation (general)..................................15 Program overview ..................................17 Programming ....................................18...
• The unit is not suitable for use in swimming pools and/or damp locations. • The AEROVITAL must be mounted in a vertical position. Mounting on inclines (e.g. walls and ceilings), is not permissible. • If the unit is to be used in a room with a heating unit that draws air from the room, prior authorisation must be obtained from the proper authorities, such as the officially appointed district chimney sweep.
- Insert the Euro mains plug of the standard connecting cable only into a suitable 230 V AC mains power supply socket. - If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, its customer service or an equally qualified person to eliminate hazards.
AEROVITAL Original operating instructions Installation Risk of damage to property by drilling holes through concealed cables or pipes! › Before installing the unit, use a suitable cable and pipe detector at the installation location to identify the presence of concealed cables or pipes in the wall (such as water pipes).
Page 7
Original operating instructions AEROVITAL On-wall mounting 1. Use a water spirit level to align the drilling template at a suitable position and attach to the wall. 2. Mark four mounting holes and the core mounting hole on the wall. Please note: •...
Page 8
AEROVITAL Original operating instructions Step 5: Fixing the pipe to the socket piece 1. Push the side of the pipe with the recessed middle bar on to the socket piece of the ventilation unit until the pipe is firmly seated.
Page 9
Original operating instructions AEROVITAL Step 7: Cable routing For fixed electrical connection (a) 1. Lift the ventilation unit and push the pipe, fixed to the unit, a little bit into the wall opening. 2. Pull the cable through the opening on the rear side of the ventilation unit.
Page 10
AEROVITAL Original operating instructions Step 9: Connecting the cable to the clamping block (only for permanent electrical connection) 1. Remove screws and cover. 2. Connect the cable to the clamping block. 3. Position cover and screw firmly into place. Note: Route the cable through the top opening on the terminal box.
Page 11
Original operating instructions AEROVITAL Step 12: Closing the front panel and testing the function 1. Hook in the front panel at the bottom of the ventilation unit. 2. Press the top of the front panel with both hands until you can hear it engage at both sides.
AEROVITAL Original operating instructions Unit description AEROVITAL 1. Casing trough 2. Display 3. Infrared receiver 4. Button 5. Casing frame 6. Front panel 7. Air inlet and outlet with cover flaps 8. Cable duct 9. Socket piece 10. Mains cable with Euro plug...
Page 13
Note! The filter is monitored on the basis of the current consumption of the unit. If the unit is operated continuously in air throughput level 1 or 2, the AEROVITAL processor switches every 8 hours for approximately two minutes to air throughput level 5, for measuring technological reasons, to check the filter.
" symbol in the AEROVITAL display. The performance of the supply air and the exhaust air unit and therefore the amount of air is adjustable in three levels. Neither blower unit is in operation when the AEROVITAL is switched off. 06.2018...
› The AEROVITAL is connected directly to the 230 V AC mains power supply. However, the voltage is transformed to 12 V low voltage in the unit. In case of overload, a safety device (thermal overload protection) in the transformer disconnects the unit from 230 V AC mains power supply and automatically switches on again when the overload has been rectified.
Page 16
• The switched air throughput levels are indicated by the corresponding number of bars in the display. Button • When it is switched on, the AEROVITAL always starts in program P1 (pollen protection program). After a voltage failure (e. g. power failure), the AEROVITAL automatically starts in the program that was last used (P1, P2 or P3).
• Three programs are selectable that can be programmed by means of remote control. • If a prolonged pause (approx. 30 seconds) occurs during the programming, without the programming having been completed, the AEROVITAL automatically switches back to the most recent operating mode. Changed values are not adopted.
• The desired room humidity can be set to a value between 30% and 90%. Programming example The AEROVITAL should operate with air throughput level 2 in basic ventilation mode and automatically increase the air throughput level from a room air humidity of 58% upwards.
Page 19
AEROVITAL Humidity control and/or room temperature control The AEROVITAL vents continuously in basic ventilation mode and automatically switches the air throughput level higher as soon as the defined values have been exceeded. • The air throughput level (1 to 4) for the basic ventilation can be freely selected •...
• Never clean the unit with a high-pressure cleaner or steam-jet cleaner. • Clean the AEROVITAL with a cloth moistened with a mild soap solution or cleaning agent. Battery replacement remote control If, when a button is pressed, no function is carried out, the batteries must be replaced.
Page 21
• The filter should be changed when this is indicated in the display - at least every six months. • Only use genuine filters from SIEGENIA. You can purchase replacement filters from SIEGENIA or from specialist retailers. Caution! Activate and remove only the specified device components.
In case of a malfunction, do not open the device or try to repair it under any circumstances. If the problem is not listed in the table below, please contact your installation firm or SIEGENIA directly: Tel. +49 271 3931-0...
Original operating instructions AEROVITAL Technical specifications AEROVITAL Air throughput Level 1 approx. 25 m³/h Level 4 approx. 35 m³/h Level 10 approx. 60 m³/h Inherent noise Level 1 = 23 dB (A) Level 4 = 30 dB (A) (measured in accordance with DIN EN ISO 3745, at 8 dB room insulation)
AEROVITAL Original operating instructions Dimensions Feedback on documentation We welcome your comments and suggestions on how to improve our documentation. Please email your comments to dokumentation@siegenia.com. 06.2018...
Siegen, 2014-11-03 S. Bauerdick (Works management) The technical documents are provided by SIEGENIA-AUBI KG. This declaration certifies conformity with the directives cited but does not warrant properties in the legal sense. The safety instructions in the product documentation supplied must be followed.
Page 28
Phone: + Industriestraße Telefax: + Wilnsdorf info@sie enia.com GERMANY www.sie enia.com Hun ary Phone: + SIEGENIA worldwide: Austria Phone: + Italy Phone: + Belarus Phone: + Poland Phone: + Benelux Phone: + Russia Phone: + China Phone: + South Korea Phone: +...