Table of Contents

Advertisement

Quick Links

OPERATING AND CARE
INSTRUCTIONS
AEROMAT VT system
AEROMAT VT WRG
AEROMAT VT WRG plus

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEROMAT VT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siegenia AEROMAT VT

  • Page 1 OPERATING AND CARE INSTRUCTIONS AEROMAT VT system AEROMAT VT WRG AEROMAT VT WRG plus...
  • Page 3: Table Of Contents

    Functions AEROMAT VT WRG / AEROMAT VT WRG plus ....... . .
  • Page 4 6.2.3 AEROMAT VT WRG – supply air filter (large filter compartment) ...... 45 7 TROUBLESHOOTING ................ 50 Error messages on the device .
  • Page 5: About This Documentation

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus About this documentation Original operating instructions These instructions are part of the original operating • assembly instructions instructions. The operating instructions consist of the • operating and service instructions...
  • Page 6: Symbols Used

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Symbols used 1.6.1 LED off LED lights up LED flashes in 1 colour LED flashes alternately in 2 colours Abbreviations Abbreviation Explanation TVOC Total Volatile Organic Compounds: volatile organic compounds in gaseous form (e. g. ethanol, carbon monoxide, methane, butane and cigarette smoke).
  • Page 7: Safety

    AEROMAT VT WRG / AEROMAT VT WRG plus Safety Intended use • The AEROMAT VT system is a ventilation system for • Depending on the environmental conditions, the ventilating and extracting air from closed rooms. AEROMAT VT system can support dehumidification in the home.
  • Page 8: Product Specifications

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Product specifications Touch control Item Name Purpose ON/OFF button • Switches the device on and off. AUTO button • Switches automatic mode on and off. • Opens the menu navigation when pressed and held.
  • Page 9: Operation

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Operation 3.2.1 Functions AEROMAT VT WRG / AEROMAT VT WRG plus Functional element Device type WRG plus Exhaust-air filter ISO Coarse ≥ 30% ● ● Outside air filter ISO Coarse ≥ 45% ●...
  • Page 10: Aeromat Vt Wrg / Aeromat Vt Wrg Plus

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 3.2.2 AEROMAT VT WRG / AEROMAT VT WRG plus • AEROMAT VT WRG and AEROMAT VT WRG plus Item name are bidirectional ventilation units (including heat Exhaust air recovery) for the ventilation of closed rooms.
  • Page 11: Temperature And Humidity Sensor

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 3.2.5 Temperature and humidity sensor • The inside temperature and humidity sensor • The outside temperature and humidity sensor measures the inside temperature as well as the measures the outside temperature as well as the inside humidity.
  • Page 12: Condensate And Frost Protection Control

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 3.2.10 Condensate and frost protection control • The condensate and frost protection control serves • The volume flow of the supply air is reduced when the device protection and secures the functioning there is an outside temperature of 5°C and an...
  • Page 13: External Inputs

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 3.2.13 External inputs • The external inputs serve to operate the ventilation • Special function – night or cross ventilation: unit via a switch (such as a series switch or rotary –...
  • Page 14: Menu

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Menu Menu level principle Menu level 1 Menu level 2 Press on button AUTO Description Change to menu level 1 8 seconds Change to menu level 2 3 seconds...
  • Page 15 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Menu level 1 Menu level 2 Explanation Bathroom control run-on time (dependent on the device equipment level) 0 min. (default value) 3 min 10 min 15 min 25 min...
  • Page 16 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Menu level 1 Menu level 2 Explanation WIFI (dependent on the device equipment level) When the ventilation unit is supplied with power, the WIFI menu can be accessed for 30 minutes.
  • Page 17: Technical Specifications

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Technical specifications 3.4.1 AEROMAT VT WRG Ventilator length 1000 mm 1200 mm Ventilator depth 320 mm 350 mm 320 mm 350 mm Without add- 55 dB 57 dB...
  • Page 18: Aeromat Vt Wrg Plus

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 3.4.2 AEROMAT VT WRG plus Ventilator length 1200 mm Ventilator depth 320 mm 350 mm Without add-on parts 52 dB 55 dB Sound absorption D n, e, w...
  • Page 19: Spare Parts

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Spare parts 3.5.1 AEROMAT VT WRG plus Name Contents Material number Exhaust air filter ISO Coarse 30% Filter set ISO Coarse L3490050-093010 Supply air filter ISO Coarse 45%...
  • Page 20 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 2. Read the filter identification (3. digit of the configuration key). SIEGENIA-AUBI KG, Duisburger Str. 8, D-57234 Wilnsdorf AE VT WRG Typ WRG AC 230V 50Hz max. 27W Vor dem Öffnen Stromzuführung unterbrechen.
  • Page 21: Initial Setup

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Initial setup Removal of locking plug 1. Open the inner panel and remove it. 2. Remove the locking plug. 3. Turn the inner panel by 180°. H47.FENS208EN-01 11.2024...
  • Page 22 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 4. Place the locking plug in the support holders for storage. 5. Suspend the internal panel. 6. Lock the internal panel. 22/52 11.2024 H47.FENS208EN-01...
  • Page 23: Integrating The Ventilation Unit Into Wifi

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Integrating the ventilation unit into WIFI 1. Install the SIEGENIA Comfort app. Integrating the ventilation unit into WIFI. Calibrating the air quality sensors • The calibration starts with a five-minute warm-up Prerequisite phase.
  • Page 24: Operation

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Operation Operation via Touch Control 5.1.1 Setting the blower level At blower level 5, the LEDs light up one after the other. 2. Activate the desired blower level by repeatedly pressing the "blower level"...
  • Page 25: Adjustment Of Menu Functions

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Adjustment of menu functions 5.2.1 Adjusting the buzzer volume 2. To change to menu level 2, press and hold the Menu level 1 Menu level 2 value "AUTO" button for 3 seconds.
  • Page 26: Adjusting The Led Brightness

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.2 Adjusting the LED brightness Error messages are always displayed, irrespective of 2. Press the "AUTO" button according to the scheme the brightness level selected. until the status LED lights up yellow.
  • Page 27: Adjusting The Led Illumination Time

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.3 Adjusting the LED illumination time 3. To change to menu level 2, press and hold the Menu level 1 Menu level 2 Value "AUTO" button for 3 seconds.
  • Page 28: Adjusting The Bathroom Control Run-On Time

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.4 Adjusting the bathroom control run-on time 3. To change to menu level 2, press and hold the Menu level 1 Menu level 2 Value "AUTO" button for 3 seconds.
  • Page 29: Adjusting The Limit For Automatic Operation

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.5 Adjusting the limit for automatic operation 3. To change to menu level 2, press and hold the Menu level 1 Menu level 2 Value "AUTO" button for 3 seconds.
  • Page 30: Adjusting The Filter Running Time

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.6 Adjusting the filter running time 3. To change to menu level 2, press and hold the Menu level 1 Menu level 2 Value "AUTO" button for 3 seconds.
  • Page 31: Switching The Preheating Register On Or Off

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.7 Switching the preheating register on or off 3. To change to menu level 2, press and hold down Menu level 1 Menu level 2 value the "AUTO" button for 3 seconds.
  • Page 32: Establishing The Wifi Connection

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.8 Establishing the WIFI connection 1. Call up menu level 1. To do this, press and hold the 3. To change to menu level 2, press and hold the "AUTO"...
  • Page 33: Switching Wifi On And Off

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.9 Switching WIFI on and off WIFI is switched on as standard on delivery. 3. To change to menu level 2, press and hold the "AUTO" button for 3 seconds.
  • Page 34: Carrying Out Wifi Reset

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.10 Carrying out WIFI reset 1. Call up menu level 1. To do this, press and hold the 3. To change to menu level 2, press and hold the "AUTO"...
  • Page 35: Coupling Si-Bus Devices

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.11 Coupling SI-BUS devices 3. To change to menu level 2, press and hold the Prerequisite "AUTO" button for 3 seconds. • All devices that are to be coupled are connected →...
  • Page 36: Decoupling Si-Bus Devices

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.12 Decoupling SI-BUS devices 3. To change to menu level 2, press and hold the Prerequisite "AUTO" button for 3 seconds. • All devices that are to be decoupled have been →...
  • Page 37: Deleting Active Faults

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.13 Deleting active faults 1. Call up menu level 1. To do this, press and hold the 3. To change to menu level 2, press and hold the "AUTO"...
  • Page 38: Restoring The Device To Factory Settings

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5.2.15 Restoring the device to factory settings 1. Call up menu level 1. To do this, press and hold the 4. Press the "AUTO" button according to the scheme "AUTO"...
  • Page 39: Care And Maintenance

    Replacing the air filter 6.2.1 AEROMAT VT WRG / WRG plus – exhaust air filter Replace the air filter every 6 – 12 months (see page 19). 1. Open the inner panel and remove it.
  • Page 40 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 2. Take the old exhaust air filter out of the device and dispose of it. 3. Insert the new exhaust air filter. 40/52 11.2024 H47.FENS208EN-01...
  • Page 41 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 4. Suspend the internal panel. 5. Lock the internal panel. 6. Press and hold the "blower level" button for several seconds to reset the filter replacement indicator. H47.FENS208EN-01 11.2024...
  • Page 42: Aeromat Vt Wrg / Wrg Plus - Supply Air Filter (Small Filter Compartment)

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 6.2.2 AEROMAT VT WRG / WRG plus – supply air filter (small filter compartment) Replace the air filter every 6 – 12 months (see page 19). 1. Open the inner panel and remove it.
  • Page 43 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 3. Turn the filter module by 180°. 4. Take the old supply air filter (1) out of the device and dispose of it. Alternatively, take the filter holder, including the old supply air filter (2), out of the filter module.
  • Page 44 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 7. Insert the new supply air filter (1) into the filter module. Alternatively, insert the filter holder, including the new supply air filter (2), into the filter module.
  • Page 45: Aeromat Vt Wrg - Supply Air Filter (Large Filter Compartment)

    11. Press and hold the "blower level" button for several seconds to reset the filter replacement indicator. 6.2.3 AEROMAT VT WRG – supply air filter (large filter compartment) Replace the air filter every 6 – 12 months (see First change the filter of the small filter compartment, page 19).
  • Page 46 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 2. Pull the filter module out of the device. 3. Turn the filter module by 180°. 4. Take the old supply air filter (1) out of the device and dispose of it. Alternatively, take the filter holder, including the old supply air filter (2), out of the filter module.
  • Page 47 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 5. Take the old supply air filter out of the device and dispose of it. 6. Insert the new supply air filter into the filter holder. 7. Insert the new supply air filter (1) into the filter module. Alternatively, insert the filter holder, including the new supply air filter (2), into the filter module.
  • Page 48 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 8. Slide the filter module into the device. 9. Suspend the internal panel. 48/52 11.2024 H47.FENS208EN-01...
  • Page 49 Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus 10. Lock the internal panel. 11. Press and hold the "blower level" button for several seconds to reset the filter replacement indicator. H47.FENS208EN-01 11.2024 49/52...
  • Page 50: Troubleshooting

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Troubleshooting Contact the producer (see page 5) if this table does not describe the error. Error messages on the device Status LED Buzzer Possible cause Solution • Check the supply voltage and power supply.
  • Page 51: Certificates

    Operating and care instructions AEROMAT VT WRG / AEROMAT VT WRG plus Certificates EU declaration of conformity We, the producer, hereby declare that our product complies with the following directives. Producer Product SIEGENIA-AUBI KG Device type: Type designation: Industriestraße 1 – 3...
  • Page 52 www.siegenia.com...

This manual is also suitable for:

Aeromat vt wrgAeromat vt wrg plus

Table of Contents