Original operating instructions AEROLIFE Contents Target group of this documentation ..............................4 Intended use ....................................4 Safety notices ....................................5 Scope of delivery .................................... 5 Installation ....................................... 6 Unit description .....................................12 Function ......................................14 Commissioning ....................................15 Operation ......................................15 Care and maintenance .................................16 Accessories ....................................18...
• Do not install the unit in contaminated rooms and ensure that no hazardous substances can be drawn in. • The unit is not suitable for use in swimming pools and/or damp locations. • The AEROLIFE may only be mounted in a vertical position. The unit may not be installed on diagonal surfaces (e. g. walls/ceilings).
Only insert the Euro plug of the standard connecting cable into a suitable 230 V AC socket. › If the mains connection cable for the device is damaged, it must be replaced by SIEGENIA, the company‘s customer service department, or similarly qualified personnel in order to prevent personal injury or damage to property.
AEROLIFE Original operating instructions Installation Risk of damage to property by drilling through concealed cables or pipes! › Before installing the unit, use a suitable cable and pipe detector at the installation location to identify the presence of concealed cables or pipes in the wall (such as water pipes).
Page 7
Original operating instructions AEROLIFE On-wall mounting 1. Align the drilling template with a spirit level and fix into place. 2. Mark four fastening drill holes and core drill hole on the wall. Notes: • The surface must be level (plastered).
Page 8
AEROLIFE Original operating instructions Step 5: Fixing the pipe to the socket piece 1. Push the pipe side with the recessed middle bar onto the socket piece of the ventilation unit until the pipe is firmly seated. 2. Fix the transition point with the adhesive tape included in the delivery.
Page 9
Original operating instructions AEROLIFE Step 7: Routing the cables With permanent electrical connection (a) 1. Lift the ventilation unit and push a small section of the attached pipe into the wall opening. 2. Draw the cable through the opening at the rear of the ventilation unit.
Page 10
AEROLIFE Original operating instructions Step 9: Connecting the cable to the clamping block (only for permanent electrical connection) 1. Remove screws and cover. 2. Connect the cable to the clamping block. 3. Put on the cover and screw firmly into place.
Page 11
Original operating instructions AEROLIFE Step 12: Closing the front panel and testing the function 1. Hook the front panel into the ventilation unit. 2. Press the front panel with both your hands until you hear the snap connection engage. 3. Plug the Euro plug into the socket, or switch on the fuse of the electrical circuit in the case of permanent electrical connection.
AEROLIFE Original operating instructions Unit description AEROLIFE 1. Housing base 2. Display 3. Button 4. Housing frame 5. Front panel 6. Air inlet and outlet with closing caps 7. Cable duct 8. Socket piece 9. Mains cable with Euro plug...
Page 13
Note! The filter is monitored by the current consumption of the unit. If the unit is continually operated at air flow level 1 or 2, the AEROLIFE-processor will switch to air flow level 5 for approx. two minutes every 8 hours in order to check the filter for measuring reasons.
“ in the display of the AEROLIFE. The performance of the supply air and the exhaust air blower unit and consequently the air flow is variable in three levels. If the AEROLIFE is switched off, the two blower units are out of operation. 08.2016...
› The AEROLIFE is connected directly to the 230-V AC mains power supply. However, the voltage is transformed to 12 V low voltage in the unit. In case of overload, a safety device (thermal overload protection) in the transformer disconnects the unit from 230 V AC mains power supply and automatically switches on again when the overload has been rectified.
• Never use cleaning agents that are aggressive or contain solvents or sharp-edged objects, as these may damage the surfaces of the casing. • Never clean the unit with a high-pressure cleaner or steam-jet cleaner. • Clean the AEROLIFE with a cloth moistened with a mild soap solution or cleaning agent. 08.2016...
Page 17
• The filter should be replaced whenever this is indicated in the display - every 6 months, at the latest. • Only use genuine filters from SIEGENIA. You can purchase replacement filters from SIEGENIA or from specialist retailers. Caution! Only activate and remove the specified unit components.
(c). 6. Reassemble the AEROLIFE in the reverse order. Note: Check the correct seating of the front panel if the AEROLIFE does not function at once after the filter exchange. Accessories Material description...
Product fiche (in accordance with EU regulation 1254/2014) a producer SIEGENIA b model identifier AEROLIFE AEROLIFE + SENSOAIR 3,1 kWh/(m² · a); G ‒ 7,8 kWh/(m² · a); F c energy consumption (SEC) ‒14,9 kWh/(m² · a); E ‒28,9 kWh/(m² · a); B energy consumption class (SEC class) ‒46,3 kWh/(m²...
Environmental protection Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act, SIEGENIA will continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are hazardous to the environment as soon as this becomes technically feasible.
Siegen, 2014-11-03 S. Bauerdick (site manager) The technical documents will be provided by SIEGENIA-AUBI KG. This declaration certifies conformity with the directives cited but does not warrant properties in the legal sense. The safety instructions in the product documentation supplied must be followed.
Page 24
Phone: + Industriestraße Telefax: + Wilnsdorf info@sie enia.com GERMANY www.sie enia.com Hun ary Phone: + SIEGENIA worldwide: Austria Phone: + Italy Phone: + Belarus Phone: + Poland Phone: + Benelux Phone: + Russia Phone: + China Phone: + South Korea Phone: +...
Need help?
Do you have a question about the AEROLIFE and is the answer not in the manual?
Questions and answers