Excessive Engine Idling
Avoid excessive engine idling. If the engine is allowed to
idle excessively it can result in glazing of the pistons due
to fuel dilution.
If the engine idles for longer than 20 minutes, a fault
code will be logged.
If the engine idles for longer than 5 minutes the
memory module will start logging the time and at
the end of the shift a Fleetmatic message will be
sent with the total idling time for that day.
The idle shut-down time can be configured by
Technical Personnel.

Using Booster Batteries

Before boost starting, machine must be properly shut
down and secured to prevent unexpected machine move-
ment when engine starts.
An explosive gas is produced while batteries are in use
or being charged.
Keep flames or sparks away from battery area. Make
sure the batteries are charged in a well ventilated area.
OPERATING INSTRUCTIONS
The machine electrical system is a 24-Volt negative
(-) ground system. Connect two 12-Volt booster bat-
teries together in series as shown for 24-Volts.
NOTE
The batteries can only be boosted if the
system voltage is above 22 Volts.
1. Switch battery disconnect switch to OFF
2. Connect one end of the positive cable to the
positive terminal of the machine batteries (A)
and the other end to the positive terminal of the
booster batteries (B). En sure a good solid
connection.
3. Connect one end of the negative cable to the
negative terminal of the booster batteries (B)
and the other end to the machine as far away
from the batteries as possible, preferably to a
machine earth point and not onto a painted
section.
4. Verify that the booster batteries are connected
in the correct order to prevent reverse battery
polarity connection.
5. Switch battery isolator switch to ON and all oth-
er electrical loads such as lights, air conditioner,
etc. OFF before starting the engine.
6. Start the engine.
7. Remove the cables. (Disconnect negative cable
first from the machine and then from the nega-
tive terminal on the booster batteries. Only dis-
connect with engine idling).
8. Disconnect positive cable.
Avoid Jump Starting
Jump starting could damage or destroy electronic con-
trol units.
Jump starting procedure is carried out at your own
risk and is not recommended.
Maintain batteries & connections in good condition
to avoid jump starting.
NOTE
The batteries can only be jump started if
the system voltage is above 22 Volts.
OPERATION