Parameters to be input:
Max. temperature, switch on/off temperature difference, speed of
the pump for solar requirements, on/off delay time
Pos : 36.59 /Tec hnische D ok umentati on Speck Pum pen/Betriebs anl eitung/Beschr eibung/BADU Omnitr onic _ BADU Om ni Stellantrieb/F unktion: Fehlerm eldung @ 20\mod_1610106365181_370.docx @ 396737 @ 3 @ 1
3.7.5

Function: Error message

Output of an error message for:
Position or start-up error of the BADU OmniTronic
Overrunning of the level control safety time
The error message persists until the error no longer exists or has
been reset.
A clocking signal output for the relay (e.g. 2 s/8 s) can also be set.
This allows a signal light or signal horn to be connected directly
(Warning indicator 2606402160).
3.7.6

Function: Timer

It is possible to program an independent timer. 10 on/off time
phases can be set.
A backwash and rinsing cycle can be activated additionally by the
timer function. The wiring must be changed for this case.
Pos : 36.62 /Tec hnische D ok umentati on Speck Pum pen/Betriebs anl eitung/Beschr eibung/BADU Omnitr onic _ BADU Om ni Stellantrieb/Niv eaureg elung @ 25\m od_1641221151268_370.doc x @ 426568 @ 2 @ 1
3.8

Level control

An output contact can be switched by a level sensor to fill up
water in the pool via a solenoid valve when the water level is too
low (e.g. after the backwash).
The optional level control is possible with a float switch at the
moment (article no. 2716900025, level switch with 10 m cable).
This is connected to the terminal points G and S1.
A safety time can also be set with the level control as protection
against overflowing. This safety cut-out comes into action when
refilling for too long. The solenoid valve is then blocked. To reset
the blocking, the float switch must be returned to the "Water level
OK" position (under consideration of the delay time). If the safety
cut-out has tripped, there is an automatic reset when the float
switch returns to the "Water level OK" position.
Parameters to be input:
Delay time on, delay time off, safety time.
The factory setting for the level control is Sensor 1. The float
switch can be connected there. However, the other two
conductive sensors that are pre-installed on the board can also be
used under the "General functions" – "Sensor level control" menu
item. For this, Niv2 or Niv3 can be selected and Niv1 set to off (---)
in "General functions".