General Functions; Frost Protection - BADU OmniTronic Translation Of Original Operation Manual

Hide thumbs Also See for OmniTronic:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 68
Description
NOTICE
The fresh water connection to a public mains for the manual and
automatic pool water supply must be made in accordance with
DIN EN 1717 with a free outfeed.
An additional board (article no. 2606402159) is available if
required. This can be mounted directly on the BADU OmniTronic
board. A conductive sensor (article no. 2606402171) can then be
connected. This requires little space. Dirt cannot stick. In addition,
this level control is not bound by temperature application limits.
Use the QR code to get a visual explanation.
NOTICE
Moisture or conductive casting gel can trip the sensor.
NOTICE
If the BADU OmniTronic is switched off and back on after
exceeding the safety time, the safety time trigger is reset. The
time for the safety cut-out may have to be increased in this case.
NOTICE
It is recommended to use a ball valve (2716070023) for hard
water. Lime deposits can occasionally prevent solenoid valves
from closing properly.
3.9

General functions

3.9.1

Frost protection

When the temperature drops below certain limits in the cold
season, the pump is switched on to prevent the pool water from
freezing. If two temperature sensors are connected, the lower of
the two temperatures is processed for the function. The frost
protection can be switched on or off generally under the Status
menu item. The factory setting is Off.
Three limit temperatures with selectable pump speed stages can
be assigned individually in the frost protection settings. It is
34 EN
03|2022