Description

3
Description
3.1.1

Accompanying valves

The control is supplied with different sized backwash valves.
BADU MAT R41 – Rp 1 ½ connections (standard)
BADU MAT R51 – Rp 2 connections (standard)
The standard versions "R41/3A" and "R51/3A" are supplied with
sealing plugs.
Further designs are available.
3.1.2

Control positions

Filter (FIL, 0°)
Drain (DR, 60°)
Closed (CLO, 120°)
Backwash (BW, 180°)
Circulate (CIR, 240°)
Rinse (RIN, 300°)
3.1.3

Menu structure

Simple navigation of the menu and input of all parameters and
specifications is possible via the keypad and the illuminated
display.
3.1.4

Keys

Arrow keys: navigate in the menu; OK key: accept/save
parameter; Esc key: back to menu
Blank key: Reset for dry run protection - keep button pressed for
3 seconds
Status BW: Press 1x briefly = status display; hold for 3 seconds =
manual start for the backwash/rinse cycle