Problem: Backwash is triggered unintentionally.
Possible causes
Interference on the circuit
board.
If triggered externally (contact),
there are devices causing
interference close to the cables
in the external contacts.
Problem: During certain procedures, the motor and the small,
blue sprocket turn in the other direction.
Possible causes
No error.
Problem: Water leaks between the valve lid and black lower
housing.
Possible causes
Leak on the shaft/lid.
Hairline tear (seldom)
Problem: Pump runs when the valve insert is transitioning
(turning).
Possible causes
Pump is not connected
correctly.
03|2022
Faults/troubleshooting
Solution
Check the
BADU OmniTronic's
surroundings and
eliminate the interference
on the circuit board or
cable.
If using a contactor, attach
an RC element.
If triggered externally, do
not lay cables with live
wires or use shielded
cables.
Solution
The motor turns the valve
insert in one direction. To
lower, change the
direction of rotation.
Solution
Replace the complete
upper part, send to the
manufacturer.
Check unit pressure and
installation conditions.
Solution
Connect the pump
correctly.
EN 51