Typical Installation; Mount Options - Graco Pulse TLM Installation, Operation And Service

Level cellular tank level monitor
Hide thumbs Also See for Pulse TLM:
Table of Contents

Advertisement

LED Pattern
LED Pattern
LED Test: when a magnet is held
against the hot spot, the LED is
briefly green, followed by briefly
red, then the LED is off.
Modem Busy: registering on the
Red LED Lit
network and sending data.
Activated: the server has
Green LED Lit
responded and activated the
server.
Beep Pattern
Beep Pattern
Low beep once per
second
High beep once per
second
Low beep once every four
(4) seconds
Low beep once every two
(2) seconds
High /Low combination
beep
Low / High combination
beep
Low double beep every
four (4) seconds
3A8551B
Function
Definition
Network registration
TCP connecting
Network / TCP listen for
commands
Re-establish network / TCP
Incoming data
Outgoing data
Network listen (data
received and the device is
active)

Typical Installation

F
. 2
IG

Mount Options

Identify a threaded opening on the top of the tank for the
device to be installed. The location should be vertical
with a clear path to the contents of the tank. There
should be no obstructions that could interfere with the
signal. Insert the threaded device by screwing it into the
opening. Do not over tighten.
1. If the hole is not threaded, place the foam gasket
(included with kit) over the opening.
2. Place the mounting adapter (included with kit) on
top of the foam gasket.
3. Use the two (2) stainless steel self-tapping,
counter-sunk screws (included with kit) to attach the
adapter to the tank. Do not over tighten.
4. Attach the device to the adapter. To form a secure
seal, make sure that the device is vertical on the
tank, that it is secured correctly to the base, and that
the threads have not crossed.
NOTE: If the tank does not contain a suitably positioned
opening at the top of the tank, reference Drilling, page
4.