EMC device classification as per the rating plate or technical data.
EMC Measures
WARNING! Electromagnetic field! Electromagnetic fields may cause health
problems that are not yet known.
It is the operating company's responsibility to ensure that there is no electro-
magnetic interference with electrical and electronic equipment.
If electromagnetic interference is detected, the operating company is obliged to
take measures to rectify the situation.
Check and evaluate possible problems and the interference immunity of equip-
ment in the vicinity according to national and international regulations:
-
-
-
-
-
Supporting measures to avoid EMC problems:
1.
2.
3.
4.
Safety Measures
A toppling device can be deadly! Set up the device securely on an even, solid sur-
at the Setup
face
Location and
-
During Transport
Special regulations apply in areas at risk of fire or explosion
-
Use instructions and checks within the company to ensure that the vicinity of the
workplace is always clean and organized.
Only set up and operate the device in accordance with the degree of protection
shown on the rating plate.
Install the device with an all-round clearance of at least 0.5 m (19.69 in.) to walls,
neighboring devices, or other objects.
Install the device at a minimum distance of 1 m (40 in.) away from IT equipment
and control lines, as well as from the welding process.
Set up the device in such a way that welding spatter cannot hit the cleaning
device.
Before transporting the device, always completely drain the parting agent.
Take care to ensure that the applicable national and regional guidelines and acci-
dent prevention regulations are observed when transporting the device, espe-
cially guidelines concerning hazards during transport and shipment.
Safety devices
Grid power lines, signal lines and data transfer lines
IT and telecommunications equipment
Devices for measuring and calibrating
The health of persons close by
Grid power supply
-
If electromagnetic interference occurs despite a grid connection that
complies with regulations, take additional measures (e.g., use a suitable
grid filter).
Shield, if necessary
-
Shield other devices in the vicinity
-
Shield the entire welding installation
Do not carry magnetic or electronic data carriers:
Magnetic or electronic data carriers can be damaged due to the magnetic
fields occurring during operation of the device.
Do not carry watches or pieces of metal. Watches may be damaged by the
operation of the device.
A tilt angle of no more than 10° is permitted.
Follow the appropriate national and international regulations.
9