Move the welding torch to the starting position above the cleaning aperture –
3
approximately 50 mm (1.97 in.) above the cleaning aperture and centrically
with respect to the middle of the cleaning aperture
-
The cleaning process is completed and the welding torch is ready for use
again
Make sure that not too much parting agent has collected at the gas nozzle
4
(no formation of drops). If this is the case:
-
reduce the injection time, or
-
after the cleaning process, blow out the welding torch with compressed
air through the hosepack
Maintain the cleaning position/
1
injection position
-
See graphic
NOTE!
During the injection process, do not
blow out compressed air through the
welding torch.
Inject parting agent into the weld-
2
ing torch for approximately
0.7 seconds