Start up the Cleaning Device

General

NOTE!
If wetting agent has not been applied to the inside of the welding torch, this may
lead to the permanent contamination of the welding torch when welding begins.
Always wet the inside of the welding torch with the manufacturer's 'Robacta
Reamer' parting agent before starting an automatic application.
To achieve optimum cleaning results, observe the following points:
-
-
-
-
NOTE!
Individual small spatters are not removed by the cleaning device.
Small welding spatters do not, however, affect the welding process.
Requirements
The following requirements must be met in order to commission the cleaning
for Commission-
device:
ing
-
-
-
-
-
-
Only if present/used
-
-
44
Always wet the inside of the welding torch with parting agent
Adhere to the specified cleaning procedures
Adhere to the specified cleaning positions
Blow out the welding torch with compressed air during cleaning (but not
while parting agent is being injected into the inside of the welding torch)
Base unit screwed tightly to the surface
Cleaning unit screwed tightly to the surface
Interconnecting hosepack of cleaning unit connected to the base unit
Base unit connected to the grid
Base unit supplied with compressed air
Base unit connected to the robot control
'Robacta Reamer' parting agent container connected to the cleaning unit
Wire cutter installed and supplied with compressed air