Service, maintenance and disposal
Before Every
1
Start-up
Daily
NOTE!
Only clean the devices with cleaning products that are free of solvents.
1
Weekly
1
2
3
4
5
Every Six
NOTE!
Months
Do not blow electronic parts clean from a short distance away.
1
Every 12 Months
1
Clean the intake
NOTE!
filter in the part-
ing agent con-
Only use the 'Robacta Reamer' parting agent provided by the manufacturer.
tainer
Its composition is specifically tailored for use with the Robacta TC. Correct oper-
ation is not ensured when other products are used.
58
Check the fill level in the 'Robacta Reamer' parting agent container and top
up if necessary
Remove any deposited parting agent and contamination from the outside of
the base unit and cleaning unit.
Empty the cleaning unit's welding residue collecting container
Clean the inside of the cleaning unit's cleaning aperture
Check the 'Robacta Reamer' parting agent container for contamination and
clean if necessary
Blow out the intake filter in the 'Robacta Reamer' parting agent container
from the inside out with compressed air using the intake hose (see section
Clean the intake filter in the parting agent container
If present, check the condition of the brush seal above the cleaning aperture.
If the brush seal is worn out, replace it
Open the base unit and cleaning unit and blow clean with dry and reduced
compressed air
Have a Fronius service technician perform a safety inspection on the cleaning
device
starting on page 58)
Need help?