STEP 1
OPTIMUM ALPHA ANGLE
(IN- FLIGHT CALIBRATION)
Setting the KLR 10 (OAA)
Set point
Turn the Calibration Mode Switch so slot is
vertical. Press the Brightness button. The
Blue Circle/Donut
on the display flashes
three times, and the unit announces
"Calibration Mode On". The system has
entered the Optimum Alpha Angle (OAA)
set-point calibration mode. As long as the
Aircraft
is
unit is at this point in the calibration routine,
flying at OAA
it flashes the
Blue Circle/Donut
display twice every five to six seconds.
To
set
Optimum Alpha
Angle
(OAA),
quickly
press
and
release
CAL SET button
Good
OAA
Set
point?
SET
GOOD
AGAIN?
Once a good OAA Set point
has been achieved, the pilot
continues to STEP 2 and MUST
enter
into
the
Calibration Mode or repeat the
OAA Set point Operation.
The
BLUE DONUT
Note 1
is in (OAA) Optimum Alpha Angle calibration mode. The system will remain at
(OAA) Set Point Mode until a valid value has been entered.
Setup and Calibration
Page 4-10
on the
an
BAD
Cruise
flashes 2 times every five to six seconds to indicate the unit
In-Flight calibration requires the pilot to climb to a safe
altitude for slow flight maneuvers. The pilot will fly the
aircraft to the condition of Optimum Alpha Angle (OAA):
Aircraft is at the Optimum Alpha Angle (OAA), when:
1. Aircraft is at a safe altitude for slow flight
maneuvers.
2. Minimum controllable flight, lower power setting,
(such as a down wind or landing pattern power
setting).
3. Able to hold altitude, 0 Vertical Speed, not
descending, zero sink (5 to 10 fpm climb OK if
your aircraft looses flight control stability at 0
VS).
4. Full aileron, elevator and rudder control, not in a
buffet, pilot to identify the set point by pitching back
slowly to a pitch no longer able to climb but able to
hold altitude with full control of the airplane.
Step B
Step A
Press
Turn
the
brightness
Calibration
button.
Mode Switch
so
slot
is
vertical.

Figure 4-2: OAA Setpoint Flowchart

the
Step C
Press
and
release
CAL
SET button to
calibrate
when
flying at (OAA).
P/N D201305000058
Rev 1 Jul 2013