Limitations - Honeywell BendixKing KLR 10 Installation Manual

Lift reserve indicator
Table of Contents

Advertisement

KLR 10 Installation Manual
5.4

LIMITATIONS

Operating Airspeed
Range:
Operating
Range:
Operating Humidity:
Operating
Temperature Range:
Storage
Temperature Range:
Voltage
range:
Electrical load:
Surge Voltage:
The RF emissions meet DO-160G environmental conditions and test
procedures for airborne equipment.
Angular Operation:
Precipitation:
Icing:
De-icing Fluid:
Appendix
Page 5-4
Minimum 35 knots TAS
Maximum 500 knots TAS
Altitude
Minimum 0 Ft MSL
Maximum 30,000 Ft MSL
Maximum 96% Relative Humidity
Minimum -20°C (-4°F)
Maximum 66°C (151°F)
Minimum -30°C (-22°F)
Maximum 85°C (185°F)
operating
Minimum 12 Volts
Maximum 28 Volts
Maximum 0.25 Amps
Maximum 56 Volts
The angle of attack limitations of this AOA
indicator vary with aircraft configuration and
calibration.
The KLR 10 probe is designed to function
properly when flown through precipitation.
The KLR 10 has optional heated probes to
prevent icing from occurring but is designed
not to be damaged if icing occurs.
No de-icing fluid restrictions on probe but
continuous spray into probe orifices could
contaminate hoses.
P/N D201305000058
Rev 1 Jul 2013