Installation Of The Klr 10 Indicator; Installation Of The If Module - Honeywell BendixKing KLR 10 Installation Manual

Lift reserve indicator
Table of Contents

Advertisement

KLR 10 Installation Manual
Step 5 - Mount the swivel base to the glareshield using the provided 4-40 mounting screws and nuts.
3.6

INSTALLATION OF THE KLR 10 INDICATOR

 In chapter two the location for the KLR 10 indicator was established. If it was determined that
additional structure or modification to the instrument panel will be required, perform that work now in
accordance with the established plan and or any required engineering data.
 Install the KLR 10 indicator and check for fit and clearances.
The KLR 10 indicator may be mounted using any two of the six threaded (6x32) mounting holes.
If utilizing side holes the screw cannot be any longer than ¼ in. plus the mounting panel
thickness. If utilizing the rear holes the screws can be no longer than ¼ in. plus the mounting
panel thickness. The angles provided with the mounting kit are provided to aid in mounting the
KLR 10 indicator in the instrument panel and their use is not mandatory.
The KLR 10 indicator was designed to be mounted in a Vertical orientation.
The KLR 10 indicator can be mounted above the glare shield with the vertical flush mount swivel
kit. This kit allows the KLR 10 indicator to be mounted and positioned so that the KLR 10
indicator is up as high in the cockpit as possible, allowing viewing of the KLR 10 without looking
down to the instrument panel.
 Route the cable from the KLR 10 indicator to the IF module location, observing the following:
Keep wires well clear of any moving controls or cables.
Physically separate electrical wire from lines or equipment containing oil, fuel, hydraulic fluid,
alcohol or oxygen.
Mount electrical wire bundles above flammable fluid lines and securely clamp to structure, in no
case may a wire be clamped to line containing flammable fluids.
3.7

INSTALLATION OF THE IF MODULE

 In chapter two, the location for the IF module was established. If it was determined that additional
structure or modification will be required, perform that work now in accordance with the established
plan and or any required engineering data.
 Attach the IF module to the airframe utilizing the four slots on the attached mounting base plate. The
IF module must be grounded for shielding. If the module is not grounded by the mounting hardware
install a grounding strap from one of the mounting screws to a suitable ground.
 Cut the KLR 10 sense lines (at a 90° angle, NO burrs) to length and insert the sense lines firmly in
the connectors, observe the color coding,
WHITE / BOTTOM
inserted approximately 3/8 in. into the connectors. Push the sense line into connector until it
stops.
 Ensure the sense line is installed correctly by giving the tubing a light pull, if the tubing does not back
out, it is a good connection.
 If you ever need to disconnect the sense lines; depress the black collar (the furthest outboard
portion of the connector) on the fitting and pull the sense line out. See help sheet included with
manual.
Installation
Page 3-6
connector TO white sense line. When correctly installed, the sense lines will be
BLUE / FRONT
connector TO blue sense line AND
P/N D201305000058