en | Configuration
Allow HTTP basic authentication
Select On if you want to allow HTTP basic authentication. This is a less secure authentication
option where passwords are transmitted in clear text. This option should only be used if the
network and system are otherwise secured.
HSTS
Select this option to use the web security policy HTTP Strict Transport Security (HSTS) to
provide secure connections.
RCP+ port 1756
To exchange connection data, you can activate the unsecured RCP+ port 1756. If you want
connection data to be transmitted only when encrypted, select the Off option to deactivate
the port.
Discovery port (0 = Off)
Enter the number of the port that you want to discover.
To deactivate the port, enter 0.
If necessary, select the Ethernet link type for interface ETH. Depending on the device
connected, it may be necessary to select a special operation type.
Network MSS (Byte)
You can set the maximum segment size for the IP packet's user data. This gives you the option
to adjust the size of the data packets to the network environment and to optimize data
transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.
Network MTU [Byte]
Specify a maximum value in bytes for the package size (including IP header) to optimize data
transmission.
4.7.3

Advanced

The settings on this page are used to implement advanced settings for the network.
RTSP
RTSP port
If necessary, select a different port for the exchange of the RTSP data from the list. The
standard RTSP port is 554. Select Off to deactivate the RTSP function.
802.1x
If a RADIUS server is employed in the network for managing access rights, authentication must
be activated here to allow communication with the device. The RADIUS server must also
contain the corresponding data.
Connect the device directly to a computer using a network cable. Network communication is
not enabled until the Identity and Password parameters have been set and successfully
authenticated.
Authentication (802.1x)
Identity
Enter the name that the RADIUS server is to use for identifying the device.
Password [EAP-MD5]
Enter the password that is stored in the RADIUS server.
Certificates [EAP-TLS]
This field shows any certificates that are already uploaded at the client level or at the server
level.
Click Configure to be redirected to the Certificates page in order to add or configure any
existing certificates.