Bosch AUTODOME 7100i User Manual page 71

Hide thumbs Also See for AUTODOME 7100i:
Table of Contents

Advertisement

AUTODOME 7100i
Status
Code
10
13**
15
16**
17
Bosch Security Systems B.V.
Description
Camera is detecting high
humidity level inside housing. The
integrity of the housing seal may
be compromised.
Autofocus has been turned off
because of excessive focus
activity.
Attempt was made to move to a
pre-position that is mapped to an
alternate function, so it is no
longer associated with a location.
Motorized zoom function is
programmed to operate at a high
usage level in the Playback Tour.
This high rate of usage could
result in premature wear of the
zoom motor.
Motor operation has been halted
due to an obstruction.
User Manual
Recommended action
(to be completed by a qualified Service
Technician)
1. Inspect the dome/housing for any cracks or
obvious damage.
2. Verify the integrity of the seals of the
camera, and mounts if applicable.
3. If damage to the seals is obvious, contact
the nearest Bosch Security Systems Service
Center.
4. Make sure the camera reaches an ambient
high air temperature on first use, to allow the
breather vent to remove possible initial
humidity.
5. If no obvious damage is found, power the
camera off and then on. If the status code
reappears, contact the nearest Bosch
Security Systems Service Center.
1. If practical, increase lighting in the scene
so that the focus function stops "hunting."
2. Use focus in manual mode or One-Push
mode.
1. Select/configure a different pre-position
number for the desired location.
2. Re-configure the pre-position assignment
so that this number is no longer associated
with an alternate function. Refer to the
subchapter "Pre-position mapping" in the
User Manual for details on re-mapping pre-
positions.
Re-configure the camera to decrease the
zoom activity to less than 30% during
recording.
1. Remove any obvious materials that are
obstructing operation of the camera pan/tilt
function.
2. If the obstruction is from ice buildup,
review the diagnostic log of the camera
(accessible from the Service menu) for errors
related to the operation of the internal
heaters. If the log shows heater failure,
contact the nearest Bosch Security Systems
Service Center.
Status codes | en