Bosch NBN-80052 Installation Manual

Bosch NBN-80052 Installation Manual

Dinion ip starlight 8000 mp
Hide thumbs Also See for NBN-80052:

Advertisement

DINION IP starlight 8000 MP
NBN-80052
en
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch NBN-80052

  • Page 1 DINION IP starlight 8000 MP NBN-80052 Installation Manual...
  • Page 3: Table Of Contents

    Mounting the camera Local storage Connection Network (and PoE power) Auxiliary power Alarm Audio Video monitor Data Configuration Setting up the camera Local set-up 7.2.1 Field of view 7.2.2 Using the install wizard Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 4 True Day/Night switching Troubleshooting LED error status Resolving problems Testing the network connection Customer service Terminal program Maintenance Cleaning Repair Reset Decommissioning 10.1 Transfer 10.2 Disposal Technical data 11.1 Specifications 11.2 Dimensions 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 5: Safety

    (NEC 800 CEC Section 60) or applicable local codes. Caution! Use only a +12 VDC power supply as an auxiliary power source. The auxiliary power supply unit must be isolated from earth. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 6: Important Safety Instructions

    Unless qualified, do not attempt to service a damaged unit yourself. Refer all servicing to qualified service personnel. Install in accordance with the manufacturer's instructions in accordance with applicable local codes. Use only attachments/accessories specified by the manufacturer. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 7: Fcc And Ices Compliance

    The user may find the following booklet, prepared by the Federal Communications Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 8: Notices

    Notice! Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of losing information, we recommend multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 9: Short Information

    All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. More information For more information please contact the nearest Bosch Security Systems location or visit www.boschsecurity.com http://www.boschsecurity.com/catalog_overview.htm Bosch Security Systems...
  • Page 10: System Overview

    The DINION IP starlight 8000 MP has three application variants: – 5MP (16:9) – 5.5MP (4:3) – 1080p 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 11: Using The Camera

    The camera recording and storage functions include local alarm recording and recording to iSCSI-based systems. The camera can also use the Bosch Video Recording Manager (VRM) to control recording and storage. Integration with the many Bosch recording solutions is seamless.
  • Page 12: Operation With External Systems

    A Bosch Video Security App is also available for remote viewing. If the camera is used in larger surveillance systems, the Bosch Video Management System offers a perfect integrated solution. Third-party integrators can easily access the internal feature set of the camera for integration into large projects.
  • Page 13 The Bosch Video Management System is a unique enterprise IP video surveillance solution that provides seamless management of digital video, audio and data across any IP network. It is designed to work with Bosch security products as part of a total video surveillance management system. Bosch Security Systems...
  • Page 14: Planning

    Verify that all parts are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. The original packaging is the safest container in which to transport the unit and can be used if returning the unit for service.
  • Page 15: System Requirements

    Internet Explorer version 11 or later – or – Application software, for example, Video Security Client, Bosch Video Client or Bosch Video Management System. Notice! Megapixel cameras can generate high bitrate streams. Ensure that your network can handle high volume traffic and that you use a powerful, high performance computer.
  • Page 16: Installation

    To attach a lens to the camera: Remove the sensor protection cap from the camera. For C-mount lenses, screw the C/CS lens adapter ring onto the camera. Screw the lens onto the camera. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 17: Lens Connector

    If a short circuit is detected on the lens connector, the lens circuit is automatically disabled to avoid internal damage. In this case, remove the lens connector and check the pin connections. DC iris lens Damp - Damp + Drive + Drive - Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 18: Mounting The Camera

    Do not expose the image sensors to direct sunlight. Do not obstruct the free flow of air around the camera. 1/4”-20 UNC The camera can be mounted either from the top or from the bottom (1/4" 20 UNC thread). 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 19: Local Storage

    MENU CVBS Unscrew the card slot cover. Slide the memory card into the slot until it locks in place. Screw the cover into place to seal the slot. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 20: Connection

    Power-over-Ethernet can be connected at the same time as a 12 VDC power supply. If auxiliary power (12 VDC) and PoE is applied simultaneously, the camera selects PoE and shuts off the auxiliary input. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 21: Auxiliary Power

    (must be 16-22 AWG stranded wire or 16-26 AWG solid wire). Loosen the screws of the supplied 2-pole connector and insert the stripped wires, then tighten the screws again. Insert the 2-pole connector into the camera power socket. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 22: Alarm

    Alarm out Use the alarm output for switching external devices such as lamps or sirens. Alarm output switching capability: – Max. voltage 30 VAC or +40 VDC. Max. 0.5 A continuous, 10 VA. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 23 A zero potential make-contact or switch can be used as the actuator (use a bounce-free contact system). Note: If IR illumination is used, the alarm interface provides a stable switching control of the day/night function of the camera. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 24: Audio

    Audio output: Line output level (not suitable for direct speaker connection); impedance 1.5 kOhm minimum; 0.85 Vrms maximum output voltage. Wiring: Use shielded audio connection cable with advised maximum cable lengths for audio line input and output levels. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 25: Video Monitor

    To connect a monitor, use the optional 3 m cable (NBN- MCSMB-30M) to connect directly to the CVBS connector of a monitor. – To connect to a coax cable, use the optional 0.3 m cable (NBN-MCSMB-03M). Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 26: Data

    This data connection supports RS485, RS422, and RS232. Note: To ensure surge and electrostatic protection, keep the cable length between the camera and external device to less than 3 meters. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 27: Configuration

    Menu button. To make a choice in the menu, press the Menu button for a short time (less that 2 s) or for a longer time. MENU CVBS NBN-MCSMB (optional) Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 28: Field Of View

    Confirm the setting by pressing MENU for a longer time. The camera reboots and assigns the factory defaults for that variant. When the variant is set correctly, briefly press MENU to continue to the following screen: 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 29 11. If the camera is not in focus, press MENU for a longer time to restart the wizard. 12. If the camera is correctly focused, briefly press MENU to exit the wizard. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 30: Configuration Via Web Browser

    To see live images in your browser it might be necessary to download and install the MPEG-ActiveX from the Bosch download store. IP Helper tool Alternatively, use the IP Helper tool to detect Bosch devices on the network: Select a camera Click Open in browser to view the camera interface.
  • Page 31: Set-Up Via Web Browser

    If required, configure the other parameters to suit your working environment (for example, ID, passwords, date and time). Refer to the operation manuals of the software for more information. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 32: True Day/Night Switching

    Set a different switching level to avoid this.) Note: If IR illumination is used, the alarm interface provides a stable switching control for the day/night function of the camera. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 33: Troubleshooting

    SD option on the for connection to Encoder Streams hardware decoder. configuration page. No connection Incorrect unit Check all established, no configuration. configuration image parameters (reset to transmission. factory default if necessary). Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 34 Audio configuration and LIVE page functions pages. The audio voice Wait until the connection is already connection is free in use by another and then call the receiver. sender again. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 35 Customer a firmware firmware file. Service and replace if upload. necessary. Incorrect firmware Enter the IP address file. of the unit followed by /main.htmin your Web browser and repeat the upload. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 36 Active proxy server in Create a rule in the contains empty network. local computer's fields. proxy settings to exclude local IP addresses. The camera LED Firmware upload Repeat firmware flashes red. failed. upload. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 37: Testing The Network Connection

    Check the IP address, subnet mask, and gateway address. Customer service If a fault cannot be resolved, please contact your supplier or system integrator, or go directly to Bosch Security Systems Customer Service. The version numbers of the internal firmware can be viewed on a service page.
  • Page 38: Terminal Program

    Enter one command at a time. When you have entered a value, such as the IP address, check the characters you have entered before pressing Enter to transfer the values to the camera. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 39 (disconnect the power supply and switch on again after a few seconds). Additional Parameters Use the terminal program to check other basic parameters and modify them where necessary. Use the on-screen commands in the various submenus to do this. Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 40: Maintenance

    Repair Notice! Never open the casing of the unit The unit does not contain any user-serviceable parts. Refer all repairs to suitable qualified specialists. 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 41: Reset

    Any changes to the settings are overwritten by the factory defaults. A reset may be necessary, for example, if the unit has invalid settings that prevent it from functioning as desired. MENU CVBS Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 42: Decommissioning

    The camera should only be passed on together with this installation guide. 10.2 Disposal Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material.
  • Page 43: Technical Data

    Video performance ‑ Dynamic range 5.5MP (4:3) mode 97 dB WDR (97+16 dB with IAE) 5MP (16:9) mode 97 dB WDR (97+16 dB with IAE) 1080p mode 103 dB WDR (103+16 dB with IAE) Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 44 Up to 8 areas with encoder quality settings per area Video resolution 5MP (16:9) 2992 X 1680 5.5MP (4:3) 2704 X 2032 1080p HD 1920 X 1080 720p HD 1280 x 720 Upright 9:16 400 x 720 (cropped) 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 45 Automatic Electronic Shutter (AES) Fixed (selectable) Default shutter Backlight Off, Auto, Intelligent Auto Exposure compensation Noise reduction Intelligent Dynamic Noise Reduction with separate temporal and spatial adjustments Contrast On/off enhancement Sharpness Sharpness enhancement level selectable Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 46 Full-duplex / half duplex Input/output Analog video out SMB connector, CVBS (PAL/NTSC), 1 Vpp, 75 Ohm Audio line in 1 Vrms max, 18 kOhm typical, Audio line out 0.85 Vrms at 1.5 kOhm typical, 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 47 Memory card slot Supports up to 32 GB microSDHC / 2 TB microSDXC card. (An SD card of Class 6 or higher is recommended for HD recording) Recording Continuous recording, ring recording. alarm/events/schedule recording Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 48 Software Unit Configuration Via web browser or Configuration Manager Firmware update Remotely programmable Software viewer Web browser, Bosch Video Client, or third party software Optical Lens mount CS mount (C-mount with adapter ring) Lens connector Standard 4-pin DC-iris connector Focus control...
  • Page 49 Bottom and top 1/4-inch 20 UNC Environmental Operating -20°C to +50°C (-4°F to 122°F) Temperature Storage -30°C to +70°C (-22°F to +158°F) Temperature Operating Humidity 20% to 93% RH Storage Humidity up to 98% RH Bosch Security Systems 2015.04 | v2.0 | AM18-Q0665...
  • Page 50: Dimensions

    DINION IP starlight 8000 en | Technical data 11.2 Dimensions 60 (2.35) 140 (5.51) 78 (3.07) mm (in) 2015.04 | v2.0 | AM18-Q0665 Bosch Security Systems...
  • Page 52 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2016...