3.1.2
Connecting Power Cable "CN1" (Fig. 3.1–[1]; Plug connector included)
The power cable is used to supply the main power to the controller.
Item
Power supply
Power capacity
Instantaneous power
failure
Grounding
The connector is CN1 (Fig. 3.1–[1])
As the cable is not attached, the user should fabricate it, using the plug connector
connected to CN1 on the controller side.
CN1 plug connector
CN1 cable clamp
Wire
The connector (JL04V–6A18–10SE–EB) is soldered to the wires.
Be sure to use the designated wires. Otherwise, fires or faults could be
caused.
When connecting the connector and wires, make sure of the terminal
arrangement.
After the connection, confirm the connection, using a tester, etc.
For the terminal arrangement, see Para. 3.1.7.
TRANSPORTATION & INSTALLATION MANUAL
Table 3.1 Power supply specifications
Single phase, AC 190 ~ 250 V, 50/60 Hz ±1 Hz
1.7 kVA
40 msec or less
Grounding with grounding resistance of 100 Ω or less
Type: JL04V–6A18–10SE–EB
Type: JL04–18CK
2
3.5 mm
~ 5.5 mm
!
DANGER
– 3–2 –
Specifications
Maker: Japan
Aviation Electronics
Industry
Maker: Japan
Aviation Electronics
Industry
2
STE 80897