1.
If the signals of SVOFF and emergency stop contacts 1, 2 are jumpered,
the controller servo power cannot be turned on.
2.
Unless the CYCLE signal is jumpered, the controller enters the cycle
operation mode.
3.
Unless the LOW_SPD signal is jumpered, the robot is operated at low
speed during automatic operation.
4.
Unless the STOP signal is jumpered, automatic operation of the robot is not
possible.