10
|
Maintenance and service

10.2.2 To clean the air outlet

10.3 Maintenance before a long stop period

Installer and user reference guide
34
rear suction
2 Clean the air filter. Use a vacuum cleaner or wash with water. If the air filter is
very dirty, use a soft brush and neutral detergent.
3 Dry the air filter in the shadow.
4 Reattach the air filter. Align the 2 hanger brackets and push the 2 clips in their
place and pull the cloth if necessary.
rear suction
5 Confirm that 4 hangers are fixed.
6 In case of bottom suction, close the air inlet grille.
7 Turn ON the power.
8 Press the FILTER SIGN RESET button.
Result: The TIME TO CLEAN AIR FILTER notification disappears from the user
interface.
WARNING
Do NOT let the indoor unit get wet. Possible consequence: Electrical shock or fire.
Clean with a soft cloth. If it is difficult to remove stains, use water or a neutral
detergent.
E.g., at the end of the season.
Let the indoor units run in fan only operation for about half a day in order to dry
the interior of the units.
bottom suction
bottom suction
FDA125A5VEB
Split system air conditioners