To Clean The Air Outlet; About The Refrigerant; Troubleshooting - Daikin FDA125A5VEB Installation And Operation Manual

Split system air conditioners
Hide thumbs Also See for FDA125A5VEB:
Table of Contents

Advertisement

▪ If the dirt becomes impossible to clean, change the air filter
(= optional equipment).
How to clean the air filter:
1 Remove the air filters by pulling their cloth upward (in case of
rear suction) or backward (in case of bottom suction).
rear suction
2 Clean the air filter. Use a vacuum cleaner or wash with water. If
the air filter is very dirty, use a soft brush and neutral detergent.
3 Dry the air filter in the shadow.
4 Reattach the air filter. Align the 2 hanger brackets and push the
2 clips in their place and pull the cloth if necessary.
rear suction
5 Confirm that 4 hangers are fixed.
6 In case of bottom suction, close the air inlet grille.
7 Turn ON the power.
8 Press the FILTER SIGN RESET button.
Result: The TIME TO CLEAN AIR FILTER notification disappears
from the user interface.
7.2.2

To clean the air outlet

WARNING
Do
NOT
let
the
indoor
consequence: Electrical shock or fire.
Clean with a soft cloth. If it is difficult to remove stains, use water or
a neutral detergent.
7.3

About the refrigerant

This product contains fluorinated greenhouse gases. Do NOT vent
gases into the atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
Refrigerant type: R410A
Global warming potential (GWP) value: 2087.5
FDA125A5VEB
Split system air conditioners
4P494410-1D – 2022.10
bottom suction
bottom suction
unit
get
wet.
Possible
NOTICE
Applicable legislation on fluorinated greenhouse gases
requires that the refrigerant charge of the unit is indicated
both in weight and CO
2
Formula to calculate the quantity in CO
tonnes: GWP value of the refrigerant × total refrigerant
charge [in kg]/1000
Contact your installer for more information.
WARNING: MILDLY FLAMMABLE MATERIAL
The R32 refrigerant (if applicable) in this unit is mildly
flammable. Refer to the outdoor unit specifications for the
type of refrigerant to be used.
WARNING
The appliance using R32 refrigerant shall be stored so as
to prevent mechanical damage and in a well-ventilated
room without continuously operating ignition sources (e.g.
open flames, an operating gas appliance, or an operating
electric heater). The room size shall be as specified in the
General safety precaution.
WARNING
▪ Do NOT pierce or burn refrigerant cycle parts.
▪ Do NOT use cleaning materials or means to accelerate
the defrosting process other than those recommended
by the manufacturer.
▪ Be aware that the refrigerant inside the system is
odourless.
WARNING
▪ R410A is a non-combustible refrigerant, and R32 is a
mildly flammable refrigerant; they normally do NOT
leak. If the refrigerant leaks in the room and comes into
contact with fire from a burner, a heater, or a cooker,
this may result in a fire (in case of R32), or the
formation of a harmful gas.
▪ Turn OFF any combustible heating devices, ventilate
the room, and contact the dealer from where you
purchased the unit.
▪ Do NOT use the unit until a service person confirms
that the part from which the refrigerant leaked has been
repaired.
8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.
WARNING
Stop operation and shut OFF the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electrical shock or fire. Contact your
dealer.
The system MUST be repaired by a qualified service person.
Malfunction
If a safety device such as a fuse, a
circuit breaker or a residual current
device frequently actuates or the ON/
OFF switch does NOT function properly.
If water leaks from the unit.
The operation switch does NOT function
properly.
8 Troubleshooting
equivalent.
equivalent
2
Measure
Turn OFF all main power
supply switches to the
unit.
Stop operation.
Turn OFF the power
supply.
Installation and operation manual