▪ If the dirt becomes impossible to clean, change the air filter.
How to clean the air filter:
1 Remove the screws on the filter cover using screwdriver.
2 Slowly pull out the air filter (composed of 3 equal parts).
3 Clean the air filter. Use a vacuum cleaner or wash with water. If
the air filter is very dirty, use a soft brush and neutral detergent.
4 Dry the air filter in the shadow.
5 Re-attach the air filter. Partially re-insert the first part of the air
filter, align the middle part of the air filter with first part and push
the 2 clips in place to lock the filter parts together. Repeat the
procedure for the last part of the filter.
6 Place the filter cover back. Fix the filter cover with screws.
7 Turn ON the power.
8 To remove warning screens, see the reference guide of the
user interface.
7.2.2

To clean the air outlet

WARNING
Do
NOT
let
the
indoor
consequence: Electrical shock or fire.
FDA200+250AXVEB
Split system air conditioners
3P580564-1E – 2022.11
unit
get
wet.
Possible
Clean with a soft cloth. If it is difficult to remove stains, use water or
a neutral detergent.
7.3

About the refrigerant

This product contains fluorinated greenhouse gases. Do NOT vent
gases into the atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
Refrigerant type: R410A
Global warming potential (GWP) value: 2087.5
NOTICE
Applicable legislation on fluorinated greenhouse gases
requires that the refrigerant charge of the unit is indicated
both in weight and CO
2
Formula to calculate the quantity in CO
tonnes: GWP value of the refrigerant × total refrigerant
charge [in kg]/1000
Contact your installer for more information.
WARNING: MILDLY FLAMMABLE MATERIAL
The R32 refrigerant (if applicable) in this unit is mildly
flammable. Refer to the outdoor unit specifications for the
type of refrigerant to be used.
WARNING
The appliance using R32 refrigerant shall be stored so as
to prevent mechanical damage and in a well-ventilated
room without continuously operating ignition sources (e.g.
open flames, an operating gas appliance, or an operating
electric heater). The room size shall be as specified in the
General safety precaution.
WARNING
▪ Do NOT pierce or burn refrigerant cycle parts.
▪ Do NOT use cleaning materials or means to accelerate
the defrosting process other than those recommended
by the manufacturer.
▪ Be aware that the refrigerant inside the system is
odourless.
WARNING
▪ R410A is a non-combustible refrigerant, and R32 is a
mildly flammable refrigerant; they normally do NOT
leak. If the refrigerant leaks in the room and comes into
contact with fire from a burner, a heater, or a cooker,
this may result in a fire (in case of R32), or the
formation of a harmful gas.
▪ Turn OFF any combustible heating devices, ventilate
the room, and contact the dealer from where you
purchased the unit.
▪ Do NOT use the unit until a service person confirms
that the part from which the refrigerant leaked has been
repaired.
8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.
8 Troubleshooting