g) Reset key

The countersunk "Reset" key is intended for resetting the room thermostat.
All settings are deleted and reset to the factory settings.
Time: 00:00
Day: Sunday
Comfort temperature: 19°C
Lowering temperature: 15°C
Switching program 1 preset for every day
Switching program 6, 7 and 8 set to a comfort temperature of 19°C
Manual mode: cleared
Output: switched OFF
Carefully actuate the "Reset" key e.g. by means of a toothpick. Do not use a
pencil or other pens containing graphite.
Graphite dust might cause a short-circuit within the electronic components.

h) DIP switch

If the cover of the room thermostat is removed, you can see a small 3-pin DIP switch.
ON
1 2 3
1 Switching over between heating mode (OFF) and cooling mode (ON)
2 Selecting a time delay (OFF = 0 minutes, ON = 5 minutes)
3 Selecting a switching threshold (OFF = 1°C, ON = 2°C)