Repair; Prepare Equipment For Repair - Graco QUANTM QTC Series Instructions Manual

Table of Contents

Advertisement

Repair

Repair
NOTE: Repair kits are available (purchase separately).
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as splashing fluid and moving
parts, follow Pressure Relief Procedure when you
stop operating and before cleaning, checking, or
servicing the equipment.
To avoid severe burns, do not touch hot fluid or hot
equipment.
Follow Prepare Equipment for Repair, page 32,
before performing any service or repair to the
equipment.
32

Prepare Equipment for Repair

To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
Always complete the following procedure before
performing any service or repair to the equipment.
1. Follow Pressure Relief Procedure, page 21.
2. Follow Flush the Equipment, page 28.
3. Verify that the equipment is turned off and power to
the system is disconnected before performing any
service or repair procedure.
4. Disconnect all fluid lines.
3A8947A