03 Product Introduction
Supported Grid Types
For the grid type with neutral wire, the voltage between the neutral wire and the ground must
be less than 10V.
TN-S
L1
L2
L3
N
PE
PE
Inverter
3.2 Application Scenarios
• The PV system is not suitable to connect equipment that relies on a stable power supply,
such as medical equipment to sustain life. Ensure that no personal injury is occurred when
the system is disconnected.
• Avoid loads with high starting current like high-power water pumps in the PV system.
Otherwise, the off-grid output may fail due to excessive instantaneous power.
• Do not start the BACK-UP function if the PV system is not configured with batteries.
Otherwise, the manufacturer shall not be liable for related system risks.
• Factors such as: temperature, humidity, weather, etc. may limit the battery's current and
affect its loading capacity.
• The inverter supports UPS, and the switching time of UPS is less than 10ms. The UPS
function may fail to start if the BACK-UP load capacity exceeds the rated power of the
inverter.
• When single overload protection occurs, the inverter can restart automatically; however,
the restarting time will be extended if it happens several times. For a faster restarting, try it
via app.
• Normal household loads can be supported when the inverter is in back-up mode. Accepted
loads as below:
• Inductive loads: 1.5P non-inverter air conditioner
• Capacitive loads: total power ≤ 0.6 times of the inverter's rated output power.
TN-C
L1
L2
L3
PEN
PE
Inverter
WARNING
8
User Manual V1.1-2022-12-20
TN-C-S
L1
L2
L3
N
PE
PE
Inverter
TT
L1
L2
L3
N
PE
Inverter