• Strictly follow the installation, operation, and configuration instructions in this guide and user manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit https://en.goodwe.com/ warranty. Safety Disclaimer...
6. All labels and warning marks should be visible after the installation. Do not scrawl, damage, or cover any label on the device. 7. Do not touch the running equipment to avoid being hurt as its temperature may exceed 60℃. Do not install the equipment at a place within children's reach.
The voltage and frequency at the connection point meet the inverter grid connection requirements. EU Declaration of Conformity GoodWe Technologies Co., Ltd. hereby declares that the inverter with wireless communication modules sold in the European market meets the requirements of the following directives: • Radio Equipment Directive 2014/53/EU (RED) •...
LED Indicators Indicator Status Explanation The inverter is power on and in the standby mode. The inverter is starting up and in the self-check mode. The inverter is in normal operation under grid-tied or off- grid modes. BACK-UP output overload. A fault has occurred.
Page 6
Product Introduction Parts 4 5 6 PV input terminal DC switch lock hole DC switch (PV+/-) Communication METER communication Communication port port (COM2) module port (COM) AC output terminal Battery input terminal BMS communication port (BAT+/-) (On-Grid and Back-Up) Indicators PE terminal 12.
Page 9
With handle: Only for Australia. Without handle: 1.2~2N·m Only for Australia. Electrical Connection PE Cable L=L1+(1-2)mm Copper, 4mm ≤S≤6mm 1.2~2N·m...
Page 14
Communication Cable (RJ45 network cable) Color EMS/PAR Orange&White 485A3 Orange 485B3 Green&White Blue Blue&White CAN_L Green CAN_H Brown&White SYN_BUS1 Brown SYN_BUS2 EMS/PAR EMS/PAR BMS or Smart Meter Color Smart Meter BMS1 BMS2 Orange&White 485_A2 485_A4 Orange 485_B2 485_B4 Green&White Blue CANH1 CANH2 Blue&White...
Page 15
Communication Module (Optional) Bluetooth Kit module: standard. WiFi Kit, LAN Kit, 4G Kit module: optional.
Page 16
Power On and Off AC breaker ON-GRID BACK-UP Power meter Utility grid Load PV string breaker Battery breaker ON-GRID loads Battery Single-pole double throw (SPDT) switch BACK-UP loads Power On Turn on Power Off Turn off...
Page 17
PV Master APP Monitoring via SEMS Portal App play SEMS Portal App Store SEMS Portal APP For more detailed instructions, scan the QR codes below. ET Series 15-30kW SEMS Portal PV Master WiFi Quick User Manual User Manual User Manual...
Page 18
Offical Website GoodWe Technologies Co., Ltd. No. 90 Zijin Rd., New District, Suzhou, 215011, China www.goodwe.com 340-00840-00 Local Contacts service@goodwe.com...