Goodwe ET Series User Manual

Goodwe ET Series User Manual

Hybrid inverter
Hide thumbs Also See for ET Series:

Advertisement

PV Master App
SEMS Portal App
SEMS Portal website
LinkedIn
Offical website
www.semsportal.com
ET SERIES USER MANUAL
JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD
No. 90 Zijin Rd., New District, Suzhou, 215011, China
HYBRID INVERTER
www.goodwe.com
340-00446-01
service@goodwe.com
Ver 1.0
2020-09-24

Advertisement

Table of Contents
loading

Summary of Contents for Goodwe ET Series

  • Page 1 PV Master App SEMS Portal App SEMS Portal website LinkedIn Offical website www.semsportal.com ET SERIES USER MANUAL JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD No. 90 Zijin Rd., New District, Suzhou, 215011, China HYBRID INVERTER www.goodwe.com 340-00446-01 service@goodwe.com Ver 1.0 2020-09-24...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION 1.1 Introduction to Operating Modes ..................01 1.2 Safety & Warnings ....................... 02 1.3 Product Overview ....................... 04 INSTALLATION INSTRUCTIONS 2.1 Unacceptable Installations ....................05 2.2 Packing List ......................... 05 2.3 Mounting ..........................06 2.3.1 Select Mounting Location ..................06 2.3.2 Mounting ........................
  • Page 3: Introduction

    The ET series of inverters from Jiangsu GoodWe Power Supply Technology Co., Ltd. (also The ET series, also called hybrid or bidirectional solar inverters, can be applied to solar systems called GoodWe) strictly complies with related safety rules for product design and testing.
  • Page 4: Product Overview

    1.3 Product Overview Safety warnings Any installation or operations on the inverter must be performed by qualified electricians in compliance with standards, wiring rules and the requirements of local grid authorities or compa- nies (such as AS 4777 and AS/NZS 3000 in Australia). Never insert or remove the AC or DC connections when the inverter is running.
  • Page 5: Installation Instructions

    Positive PV Plug Negative PV Plug Bracket With 3 CT Negative BAT Both sides -------- 200mm 500mm Fixed Expansion bluetooth Wi-Fi ET SERIES USER MANUAL HYBRID INVERTER Quick Installation AC Cover Terminal Screw Terminal Bolts Module Module User Manual Instructions...
  • Page 6: Mounting

    2.3.2 Mounting Step 3 The inverter must not be installed near flammable or explosive materials or near The ground cable shall be connected to the ground plate on the grid side. equipment with strong electromagnetism. The inverter is suitable for mounting on concrete or other non-combustible surfaces only. Step 1 Please use the mounting bracket as a template to drill 4 holes in the correct positions (e.g.
  • Page 7: Electrical Wiring Connections

    22A) Make sure that the battery switch is off and that the nominal battery voltage meets ET series specifications before • The minimum isolation resistance to ground of the PV string must exceed 19.33kΩ in case of any connecting the battery to the inverter.
  • Page 8: On-Grid & Backup Connections

    2.4.3 On-Grid & Backup Connection Step 2 An external AC breaker is needed for the on-grid connection for isolation from the grid when Place the AC cable through the terminal cover necessary. as shown in the figure. Note: Backup function is optional for only German market, even though the hardware connector is always there.
  • Page 9: Smart Meter & Ct Connections

    The inverter will restart itself if overload protection is triggered. The preparation time for restarting will be increasingly long (one hour at most) if an overload recurs. Take the following steps to imme- For details please refer to the technical parameters in the ET series inverter section (Page 29). diately restart the inverter.
  • Page 10: Bms Connection

    "DRED Port" as shown in the figure. 2.6 Earth Fault Alarm Connection ET series inverters comply with IEC 62109-2 13.9. The fault indicator LED on the inverter cover will light up and the system will email the fault information to customer.
  • Page 11 Wiring system for the ET series hybrid inverter System connection diagrams Note: This diagram indicates the wiring structure of the ET series hybrid inverter, not the electric wiring Note: According to Australian safety requirements, the neutral cables of the on-grid side and backup side standard.
  • Page 12: Manual Operation

    Alarm warning Save success! Backup Switch Master OPERATION INSTRUCTIONS from Please select your current wireless network Anti-Reverse Function Switch Off Click "Complete". the current configuration will take effect after www.goodwe.com a restart. SSID AUTH/ENCRY RSSI Channel Overview Param If you still need to configure the other pages of information,...
  • Page 13: Other

    OTHER 4.1 Error Messages The error messages shown below will be displayed on the PV Master App or reported by e-mail if an error occurs. ERROR MESSAGE EXPLANATION REASON SOLUTIONS The inverter has detected that the phase angles of L2 and L3 Utility Phase Failure The sequence of the on-grid wire is incorrect The L2 and L3 cables are connected in reverse order.
  • Page 14: Troubleshooting

    4.2 Troubleshooting Problems During Operation Checks Before Turning On AC Power ET does not start up with battery only • Battery connections: Confirm that the connections between the ET and battery and that the Solution: polarities (+/-) are not reversed. Refer to figure 4.2-1 Make sure that the battery voltage is greater than 180V.
  • Page 15 A: Normally the Solar-Wi-Fi* signal can be seen immediately after inverter has powered up. A: For the ET series inverter, it can connect to lithium batteries which have compatibility with However, the Solar-Wi-Fi signal will disappear when the ET connects to the internet. If changes ET-series inverters with nominal voltages from 180 V to 600 V.
  • Page 16: Disclaimer

    4.3 Disclaimer About the Smart Meter And Power Limit Function The ET series inverters are transported, used and operated under environmental and electrical Q: How to activate the output power limit function? conditions. The manufacturer has the right to not provide after-sales services or assistance under...
  • Page 17: Technical Parameters

    4.4 Technical Parameters Technical Data GW5KL-ET GW6KL-ET GW8KL-ET GW10KL-ET Protection Technical Data GW5KL-ET GW6KL-ET GW8KL-ET GW10KL-ET Integrated Anti-Islanding Protection Battery Input Data PV String Input Reverse Polarity Protection Integrated Battery Type Li-Ion Insulation Resistor Detection Integrated 180~600 Battery Voltage Range (V) Integrated Residual Current Monitoring Unit Max.
  • Page 18 Technical Data GW5K-ET GW6.5K-ET GW8K-ET GW10K-ET Technical Data GW5K-ET GW6.5K-ET GW8K-ET GW10K-ET Protection Battery Input Data Anti-Islanding Protection Integrated Battery Type Li-Ion Integrated PV String Input Reverse Polarity Protection Battery Voltage Range (V) 180~600 Insulation Resistor Detection Integrated Max. Charging Current (A) Integrated Residual Current Monitoring Unit Max.
  • Page 19: Other Tests

    4.5 Other Tests Appendix protection category definition Overvoltage category definition For Australian requirements, in the THDi test, Zref should be added between the inverter and mains. Applies to equipment connected to circuits where measures have been RA, XA for the line conductor Category I taken to reduce transient overvoltages to a low level.
  • Page 20 Pollution degree definition No pollution or only dry, non-conductive pollution occurs. Pollution Degree I The pollution has no influence. Normally only non-conductive pollution occurs. Occasionally, Pollution Degree II however, temporary conductivity caused by condensation is expected. Conductive pollution occurs, or dry, non-conductive pollution Pollution Degree III occurs, which becomes conductive due to condensation, which is an expected condition.