WATCHDOG OPERATION

Watchdogs are present to provide an indication that something has gone wrong. Systems that are
programmable can hang for a number of di erent reasons. One of the most common is the execution of an in nite loop due to a programming logic
error. This type of failure prevents any of the other code from executing. Also, if an unusual number of interrupts arrives during a single cycle of the
loop this can prevent the main loop from having su cient time to execute. Another possibility is a failure in hardware that causes a constant reset.
Each controller has an internal hardware watchdog that is continuously running in the background to monitor
for a system malfunction. This watchdog is not user serviceable and is not visible to the user. It will trigger in the event of a task timeout and can only
be reset through a hard reset of the controller, which means that the user must connect the service tool to the controller, tie PWM 1 & 2 to supply
voltage, and then power up the unit. This will prevent the application code from loading
10.5

CONTROLLER MEMORY

The controller utilizes an advanced superscalar
32 Bit processor operating at 200 MHz. The memory is arranged into the following areas:
ROM Flash 3.75 Mbyte
EEPROM128 kbyte reserved for internal use i.e. rmware/bootloader
RAM 256 kbyte
MRAM 32 kbyte (4 kbyte user accessible calibration parameters)
10.6

CALIBRATION VARIABLES

See HFX CAPI Calibration Memory User Guide for more information