Oneida Air Systems XXS050333 Owner's Manual

High vacuum dust collector with smart boost

Advertisement

Quick Links

OWNER'S MANUAL
High Vacuum
Dust Collector
with SMART Boost
5 HP
# XXS050333
U.S. Patent: #8491685,
#8514090, #8496719,
#7247180
Appearance may vary slightly
Rev: 05/10/2021
Doc. #ZBM000104

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems XXS050333

  • Page 1 OWNER’S MANUAL High Vacuum Dust Collector with SMART Boost 5 HP # XXS050333 U.S. Patent: #8491685, #8514090, #8496719, #7247180 Appearance may vary slightly Rev: 05/10/2021 Doc. #ZBM000104...
  • Page 3: Table Of Contents

    Table of Contents System Start-Up Information System Specifications System Dimensions System Contents Assembly Instructions Maintenance Troubleshooting F.A.Q. Recommended Accessories Warranty Information Notes oneida-air.com...
  • Page 4: System Start-Up Information

    5. Check amperage draw on motor with all gates open. Current draw should not exceed maximum motor amperage as stated on motor plate. (Oneida Air Systems is not responsible for damage to motors caused by improper installation, wiring or failure to follow these directions).
  • Page 5 System Start-Up Information (Continued) d. NFPA664 Code book, “Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities”, applies to woodworking operations that occupy areas of more than 5,000 sq. ft. or to areas where dust producing equipment requires an aggregate dust collection flow rate of more than 1,500 cfm (cubic feet per minute).
  • Page 6: System Specifications

    Filter Media Type Izumi Axtar Spunbond Media Filter Efficiency 99.9% @ 0.2-2.0 microns Filter Surface Area 220 Sq. Ft. SYSTEM DIMENSIONS AND CONSTRUC TION Barrel/Cyclone Body Heavy-gauge cold-rolled steel Inlet 7" Diameter Overall Height (with 55 Gallon Drum) 106" Oneida Air Systems...
  • Page 7: System Dimensions

    System Dimensions Nominal dimensions shown with a 55 gallon drum. Dimensions subject to slight variations in manufacturing. Top View 48" 219 mm 18" 30" 457 mm 762 mm 106" 2,692 mm 87-1/2" 2,223 mm 78-1/2" 1,994 mm 68" 1,727 mm 36"...
  • Page 8: System Contents

    You will need the following tools: GENER AL FAN HOUSING FILTER 8' Ladder Razor Knife Flathead Screwdriver 7/16" Wrench Level Diagonal Cutters Hammer 7/16" Socket Wrench Scissors Tape Measure / Ruler 1/2" Wrench 1/4" Socket 1/2" Socket Wrench Impact Driver Oneida Air Systems...
  • Page 9 System Contents (Continued) Note: Sent out attached × 4 to the Motor Assembly (A) × 4 × 7 × 4 × 7 × 8 × 8 × 12 × 6 × 24 × 6 × 12 × 8 × 6 ×...
  • Page 10: Assembly Instructions

    INLET Filter will obstruct inlet pipe Assemble the Stand (R) and Stand Extensions (S) [FIG 1]. Refer to the instruction sheets included: • Stand Instruction Sheet # ZBI000014 • Leg Extension Instruction Sheet # ZBI000013 FIG. 1 Oneida Air Systems...
  • Page 11 Assembly Instructions (Continued) Apply Gasket (Q1) making sure that there is no gap where the ends meet: a. Apply to the top flange of the Cone (D) inside the bolt holes [FIG. 2a]. Top View Top View b. Apply to the top rim of the Barrel (C) outside of the bolt holes [FIG.
  • Page 12 [FIG. 5] Secure the Fan Housing onto the Barrel using eight Flange Bolts (Q3) and eight Flat Washers (Q4). FIG. 5 10 Oneida Air Systems...
  • Page 13 Assembly Instructions (Continued) THE MOTOR ASSEMBLY IS VERY HEAVY AND CUMBERSOME; BE SURE TO HAVE ADEQUATE Ÿ HELP WHEN LIFTING! Carefully lift Motor Assembly (A) to top of Fan Housing (B) and align the Fan Housing holes with the motor plate holes following the orientation shown in [FIG.
  • Page 14 8" Plenum Elbow (J) [FIG. 8a]. Mate the Elbow to the 8" Outlet Adapter (I) and close the Clamp over the rolled ends. [FIG. 8b] Lock the Clamp in place using the provided cotter pin [FIG. 8c]. FIG. 8a FIG. 8b FIG. 8c 12 Oneida Air Systems...
  • Page 15 Assembly Instructions (Continued) Attach each Dual Filter Adapter Bracket (O7) to the Dual Filter Plenum Plate (N) with two Hex Head Bolts (O7A), two Flat Washers (O7B) and two Whiz-Lock Nuts (O7C) as shown in [FIG. 9A] and [FIG. 9B]. FIG.
  • Page 16 Note: The hose is a snug fit. Pull ends up little by little to work the hose onto the cyclone’s discharge. Pliers can be used to grab the reinforcing wire and aid in pulling the hose over the opening. FIG. 12b 14 Oneida Air Systems...
  • Page 17 Assembly Instructions (Continued) Insert the Drop-In Silencer (O1) into the top of the Filter (P) [FIG. 13]. FIG. 13 Attach each Filter (P) to the Dual Filter Plate (N) with four J-Bolts (O4), four Flat Washers (O3) and four Thumb Nuts (O2) as shown in [FIG.
  • Page 18 Filter Plate (N) under the Thumb Nut (O2), then attach the alligator clip to the filter’s cage [FIG. 16]. Note: If you need to extend the wire, you can use any 16 gauge copper stranded wire and connect with wire nuts. FIG. 16 16 Oneida Air Systems...
  • Page 19 Assembly Instructions (Continued)  The flex hose connects the cyclone to the dust bin below and only requires enough height to allow the lid to be lifted from the bin. You may shorten the provided 1’ hose length as needed. Attach Hose (F) to the Cone’s (D) discharge, and secure it in place with the Clamp Band (E).
  • Page 20 ENSURE THAT ALL ELECTRICAL POWER TO THE SYSTEM IS DISCONNECTED BEFORE Ÿ PROCEEDING WITH FURTHER STEPS. Use the adhesive of your choice to temporarily secure the starter to the wall [FIG. 19]. To permanently secure the starter to the wall proceed to Step 20. FIG. 19 18 Oneida Air Systems...
  • Page 21 Assembly Instructions (Continued) To permanently secure the starter to the wall, Mounting Screws Holes take off the starter cover by removing the top and bottom screws and exposing the overload and contact connections [FIG 20a]. Set aside the screws. START a.
  • Page 22: Maintenance

    Corrosion Severe Dirt; > 122° F (50° C) Extreme Abrasive Dust; or Class H Insulation* Corrosion < -22° F (-30° C)** Temperature * Special HIGH temperature grease is recommended ** Special LOW temperature grease is recommended 20 Oneida Air Systems...
  • Page 23: Troubleshooting

    2. If there is no room to remove the cowling, unplug your system for 1 minute.  If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service Department at 1-866-387-8822 or email support@oneida-air.com. oneida-air.com...
  • Page 24: F.a.q

    What dust can be collected? Oneida Air Systems’ dust collectors are designed and tested for wood and wood dust. They can and have been used effectively for various other dusts and chips, such as drywall dust, paper dust, agricultural dust, metal chips and other forms of debris.
  • Page 25 F.A.Q. (Continued) Where do I mount the included Dust Sentry? The strobe can be mounted anywhere convenient that is within reach of the wiring. Can I lengthen the Bin Level Sensor power cord? The 8' power cord can be extended to any length using wire of the same gauge or higher. Why does the Bin Level Indicator flash when the bin is empty? Because the Dust Sentry works via an adjustable infrared sensor, it can sometimes show false positives with an empty container because of the reflective surface at the bottom of the steel drum.
  • Page 26: Recommended Accessories

    RF Remote Control Key Fob #AMR000000 • Sends long range wireless signal via radio frequency. • Works at long distances and even through walls! • Compatible only with systems that include a magnetic motor starter control box. 24 Oneida Air Systems...
  • Page 27 Universal Drum Dolly #SDD990000 • Fits nearly any cylindrical waste bin sold by Oneida Air Systems. • Includes five 2" non-marking caster wheels (3 non-locking, 2 locking). • Requires Leg Extension Kit (Item #STZ212301) if used with a stand mounted system.
  • Page 28: Warranty Information

    In no event shall Oneida Air Systems’ liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga.
  • Page 29: Notes

    Notes oneida-air.com...
  • Page 30 Regardless of where you purchased your system, if you have any questions or issues with missing / damaged parts, please call Oneida Air Systems first to let us help resolve your problem. We fully stand behind the quality of our products and place the utmost value on customer satisfaction.

Table of Contents