Oneida Air Systems Super Dust Gorilla 2hp Owner's Manual

Oneida Air Systems Super Dust Gorilla 2hp Owner's Manual

Hide thumbs Also See for Super Dust Gorilla 2hp:

Advertisement

2 / 2.5 / 3 & 5hp
Super Gorilla Owner's Manual
Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, NY 13204
Phone 1.800.732.4065 315.476.5151 Fax 315.476.5044 www.oneida-air.com
Shown with
optional Stand.
Models may vary slightly
in appearance.
9_11

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems Super Dust Gorilla 2hp

  • Page 1 2 / 2.5 / 3 & 5hp Super Gorilla Owner’s Manual 9_11 Shown with optional Stand. Models may vary slightly in appearance. Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, NY 13204 Phone 1.800.732.4065 315.476.5151 Fax 315.476.5044 www.oneida-air.com...
  • Page 2: Table Of Contents

    Thank You for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only. Our qualified technicians and sales staff are available 7:30am - 6:00pm EST Mon. - Thurs. and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection.
  • Page 3: System Start-Up Information

    I. System Start-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual 2. Install ductwork completely before operating collector: A.) Seal ductwork with silicone sealant or duct tape. B.) Have dust bin in place and sealed. 3.
  • Page 4: Commercial Configurations

    II. Super Dust Gorilla Configurations Caution: If exhaust air is vented outside you must provide make up / return air. Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. External Cartridge Filter - Silencer Included with Filter Cartridge Filter Media 95 Sq.
  • Page 5: General Specifications & Fan Performance Curve

    III. General Specifications & Fan Performance Curves Allow 1 - 2” from (2hp) 2158 CFM - (2.5hp) 2959 CFM - Free Fan Rating ceiling for motor (3hp) 2331 CFM - (5hp) 2976 CFM - Free Fan Rating venting. System (2hp) 1349 CFM @ 2.3” SP w/ Filter Performance (2.5hp) 1440 CFM @ 2.3”...
  • Page 6: Dimensions

    IV. Dimensions For Minimum Mounting Heights w/ 39” Filter *Dimensions subject to slight variation in manufacturing. 49” / 53” 13.00 (2hp) 18.00 (2.5 - 5hp) 66.50” 2 / 2.5 / 3hp (2 / 2.5hp) 68” 3 & 5hp 8.00 (3 / 5hp) 2 &...
  • Page 7: General Assembly

    V. General Assembly 1. Motor Assembly - (2hp) BXI002105 / (2.5hp) BXI002505 (3hp) BXI012105 / (5hp) BXI002305 1a. 2hp motor - BMZ020105 / 2.5hp - BMZ025105 Filter Grounding Wire - FGA000000 3hp motor - BMZ030170 / 5hp - BMZ050170 (8) 5/16” Clips (8) 5/16”...
  • Page 8 VI. Assembly Instructions Instructions for assembly of the Fan Blower Housing and Barrel of the Oneida Models. 1. Push clips onto inside circle on Fan Housing, making sure clip is pushed all of the way on, that the bolt holes are in alignment with the clip holes and that the small barrel on the clip is on the INSIDE of the Fan Housing as shown in diagram.
  • Page 9: General Assembly Instructions

    VI. General Assembly Instructions Do NOT use hook on motor to lift unit. There are essentially three ways to assemble your collector and to at- tach it to the stand. The way that is right for you should be determined by expertise and manpower available.
  • Page 10: Bracket Assembly

    Flex Hose Connection Cone to Drum Distance between drum lid and cone can vary. Some systems have little space there to minimze overall system height. The hose is used to seal between the drum and system and needs only enough height to allow the lid of the drum to come off. In some cases the flex hose will have to be cut down (especially with stands or when mounting the system as low as possible).
  • Page 11: Filter Assembly

    VIII. Filter Assembly 2hp Filter Plate 4 hole side is near dust collector. External 39” Filter Assembly Gasket *Silencer Included 1. Attach gasket to collector outlet making sure there are no gaps where gasket ends meet. 2. Attach Plenum to outlet using the included (7) 3/8 x 1”...
  • Page 12: Filter Maintenance

    IX. Filter Maintenance External Filter Cartridge Cleaning Intervals When unit is turned off, use compressed air to blow dust off from exterior of filter. Hold nozzle at least 6” away from filter pleats*. Do not remove bottom dust pan before or during the blow-off process! Let dust settle into dust pan.
  • Page 13: Directions For Cleaning External Filter & Clipping Dust Pan

    X. Directions for Cleaning External Filter All steps should be done with a dust mask and eye protection. Proper filter clean- ing should not be neglected. A dirty filter can affect dust collector operation and filter life. 1. Compressed air from outside. Blast air along pleats of the filter at about a 20 degree angle.
  • Page 14: Fan / Blower Wiring Diagram

    XI. Wiring Diagram for Magnetic Starter (220v, 1 **)* Baldor TEFC Motor 6’ Long Type SJT Note: Overload is preset at factory 14 AWG Power Cord ( 2 / 2.5 / 3hp) 12 AWG Power Cord (5hp) However, if for some reason you need to set the over- load, use the instructions below.
  • Page 15: Troubleshooting

    Note: If you continue to experience difficulty Motor Overheating with your collector, call The motor’s internal circuit breaker will trip if the motor is overheating. Oneida Air Systems at Motor amperage too high - Shut system down. 1.800.732.4065 for assis- tance. Caused By: System should be completely bolted and sealed together.
  • Page 16: Fire Hazards

    XIII. Fire Hazards - Read Before Installing and Operating Oneida Collectors are designed for WOOD DUST only!! Wood shaping and cutting processes generate wood chips, shavings, and dust. These materials are considered combustible. Air borne wood dust below 420 microns in size (,017 of an inch) in certain concentration ranges when ignited can deflagrate (burn quickly). An ignition source such as a spark or ember can ignite a dust mixture resulting in an expanding flame front which can cause an explo- sion if tightly contained.
  • Page 17: Terms And Conditions

    Returned Goods Policy Buyer must inform Oneida Air Systems of any shortage or damage, by so noting in writing, on the freight delivery bill prior to signing to indicate receipt of shipment. All claims covered under the limited warranty, are subject to inspection and investigation by Oneida Air Systems. Oneida Air Systems reserves the right to inspect and investigate all returned products before Buyer’s claim is settled.
  • Page 18: Stand Assembly

    XV. Stand Assembly 35 & 55 Gal. Stand - STG000035 / STG000055 Top Gusset Stand Kit Contents Stand Brace Hardware Kit (1) - AHX000100 Mid - Gusset 56”/ 68” Rubber Leg Cap (4) - RCR012500 Top Gusset (4) - RFG010000 Rubber Leg Cap 27.5”...
  • Page 19: Accessories

    XVI. Accessories Bolt Together Stand STG000035 - 35 Gal. Stand STG000055 - 55 Gal. Stand Replacement Filter w/ Pat. Pend. Flame Guard Arrestor FCS133695HF (2hp) / FCS183600HF (2.5/3/5hp) 13”x 36” / 95 Sq. Ft. - GE Certified (H-12) HEPA Media / MERV 16+ rated 18”x 36”...
  • Page 20: Fan Motor Maintenance

    XVII. Fan Motor Maintenance Per Baldor specifications, their 2 pole motors (3600 RPM) motors are to be relubricated every 5500 hours. Combined Super Gorilla Owner’s Manual © O.A.S. 2010...
  • Page 21: Optional Remote Controller Diagram

    XVIII. Optional Remote Controller Diagram Applies If You Have the Remote Controller Type: MS1 MS1-XXD 1 (3) X7 NXX XP-RW Voltage: AC100 - 120v / 50-60 Hz and AC220 - 240v / 50-60 Hz (or appoint other voltage) Frequency: 303.9 MHz Temperature: -5 C to 60 C Action Mode: ON Blue - Motor Start / OFF Red - Motor Stop Remote Controller Diagram...
  • Page 22: Optional Filter Efficiency Gauge Mounting Instructions

    XIX. Filter Efficiency Gauge Mounting Instructions Air Flow to Filter Up to 8’ away Silicone Washer Metal Plenum Mounting Instructions Air Flow to Filter 1. Select a location free from excessive vibration and where ambient temperature is between 20 F to 120 F (-6.7 C to 49 C). You can mount gauge up to 8’...

Table of Contents