Machinery Under $50,000 Shown with optional Filter Flame Guard Stand and Drum. Arrestor - U.S. Pat. # 8,496,719 Models may vary slightly in appearance. Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, NY 13204 Phone 1.800.732.4065 315.476.5151 Fax 315.476.5044 www.oneida-air.com...
Thank You for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only. Our qualified technicians and sales staff are available 8:30am - 5:00pm EST Mon. - Fri. to answer any questions concerning OAS products and dust collection. Call for duct- work design and ductwork quotes, including system pricing and shipping cost.
I. System Start-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual 2. Install ductwork completely before operating collector: A.) Seal ductwork with silicone sealant or duct tape. B.) Have dust bin in place and sealed. 3.
II. Features External Cartridge Filter - Silencer Included with Filter Cartridge Filter Media GE Certified (H-12) HEPA Media. MERV 16+ rated. Pat. Pend. Flame Guard Arrestor Filter Grounding Wire Included Dust Sentry™ Optional Wall Bracket Included Silencer Included Remote Starter Do Not Remove Pat.
VI. Bracket Assembly 26 1/4” Slots in the brackets are .406” x 1.00”. 24” Note: Bolts included to mount bracket to collector. Hardware NOT included to mount to wall. 1. Hold bracket against wall with top of plate at 56” for 35 gal. drum or 69”...
VI. General Assembly Instructions Do NOT use hook on motor to lift unit. With all assemblies, make sure rectangular air outlet is oriented on Fan/Blower housing as you are looking down as in Fig. 1A or facing it as shown in diagrams. This is very important. Before you start, make sure you have cut and placed the provided gasket material on top and bottom of the Fan / Blower housing and the Cone as shown in the diagrams.
Page 10
VI. General Assembly Instructions (Cont.) 6. Attach (2) U-Spring clips (AFT010916) to either side of the motor with the flat side of the clip facing out. Motor cowling will not fit otherwise. Put cowling (BHX001803) over the motor and attach with (2) sheet metal screws (AFS010075) on each side by screwing into spring clips.
VII. Drum Assembly Drum Grounding Wire Distance between the drum lid and cone can vary. Some systems have little space there to To attach the Drum Grounding Wire, start a minimize overall system height. small hole in bottom of In some cases, the flexible hose will have to be cone above flex hose and in the top of the cut down (especially with stands).
IX. Starter Assembly Plug in Starter You can attach your Control Box to a wall by screws, or to your collector by double sided velcro or magnets or you can just set it on the dust bin top. You must let your dust collector completely stop before you restart your collector. If you can’t restart your collector, see the Troubleshooting section of the manual.
X. Stand Assembly 35 & 55 Gal. Stand - STG000035 / STG000055 Top Gusset Stand Kit Contents Stand Brace Hardware Kit (1) - AHX000100 Mid - Gusset 56” / 68” Rubber Leg Cap (4) - RCR012500 Top Gusset (4) - RFG010000 Rubber Leg Cap 27.5”...
Filter Grounding Wire Figure 1 Attach the ring terminal on the green ground wire from the motor to a bolt on the filter plate, under the nut. Then attach the alligator clip to the filter cage as shown in Fig. 1. XI.
XII. Directions for Cleaning the Filter All steps should be done with a dust mask and eye protection. Proper filter clean- ing should not be neglected. A dirty filter can affect dust collector operation and filter life. 1. Compressed air from outside. Blast air along pleats of the filter at about a 20 degree angle.
XIV. Accessories Bolt Together Stand STG000035 - 35 Gal. Stand STG000055 - 55 Gal. Stand Replacement Filter w/ Pat. Pend. Flame Guard Arrestor FCS183600HF 18”x 36” / 110 Sq. Ft. GE HEPA (H-12) Filter Media. Dust Containers 55 Gal. Steel The BAG Gripper ABX000000 The BAG Gripper provides the ability to use convenient plastic bags inside...
Note: If you continue to experience difficulty Motor Overheating with your collector, call Oneida Air Systems at The motor’s internal circuit breaker will trip if the motor is overheating. 1.800.732.4065 for assis- Motor amperage too high - Shut system down.
XVI. Fire Hazards - Read Before Installing and Operating Oneida Collectors are designed for WOOD DUST only!! Wood shaping and cutting processes generate wood chips, shavings, and dust. These materials are considered combustible. Air borne wood dust below 420 microns in size (.017 of an inch) in certain concentration ranges when ignited can deflagrate (burn quickly). An ignition source such as a spark or ember can ignite a dust mixture resulting in an expanding flame front which can cause an explo- sion if tightly contained.
Returned Goods Policy Buyer must inform Oneida Air Systems of any shortage or damage, by so noting in writing, on the freight delivery bill prior to signing to indicate receipt of shipment. All claims covered under the limited warranty, are subject to inspection and investigation by Oneida Air Systems. Oneida Air Systems reserves the right to inspect and investigate all returned products before Buyer’s claim is settled.