Oneida Air Systems XXK050100 Owner's Manual

Oneida Air Systems XXK050100 Owner's Manual

5 & 75 hp direct drive cyclonic dust collectors

Advertisement

Quick Links

5 & 7.5 HP
Direct Drive Cyclonic
Dust Collectors
Owner’s Manual
Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, N.Y. 13204
Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www.oneida-air.com

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems XXK050100

  • Page 1 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors Owner’s Manual Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, N.Y. 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www.oneida-air.com...
  • Page 2 Thank You for Choosing an Oneida Air Systems Product! Read the entire Owner’s Manual before installing or operating system! Proudly Made in the U.S.A. Table of Contents Page Read Before Installing System 5 - 7.5 HP Direct Drive Owner’s Manual...
  • Page 3: System Start-Up Information

    I. System Start-Up Information Caution The Dust Collector & Fan/Blower is heavy. Handling and installation should always be performed by experienced and trained personnel who have experience with rotary equipment. In addition to the following instructional manual, care should be taken to ensure compliance with specific safety requirements mandated by federal, state and local codes.
  • Page 4: General Assembly

    Never allow gauge to reach 5”. 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors Owner’s Manual Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, N.Y. 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www.oneida-air.com Caution Check Dust Bin Frequently For Smoldering Materials. Empty Bin Before Leaving Shop.
  • Page 5 III. General Specifications & Fan Performance Curves Physical and Electrical Data for 5 and 7.5hp Direct Drive Systems. System Performance Dust Bin System Dimensions Options Integral Fan Blower - 5hp External Cartridge Filters (2) Integral Fan Blower - 7.5hp System Curves 5 &...
  • Page 6 IV. Dimensions 5 - 7.5 HP Direct Drive Owner’s Manual O.A.S. 2008...
  • Page 7 V. Angle Iron Stand Stand Hardware: Requires Fork Truck for installation. 5 - 7.5 HP Direct Drive Owner’s Manual O.A.S. 2008...
  • Page 8 VI. Assembly Instructions Fan / Blower is shipped strapped to Cyclone Barrel. It is NOT attached to the unit. You must bolt them together. Follow the instructions below. Oneida Air recommends having at least two people for assembly. System is heavy. Cyclone Inlet and Fan / Blower are independent.
  • Page 9 VI. Assembly Instructions See Ill. 5. IMPORTANT: Do not operate the collector until the dust bin is in place and the connector is air tight or motor damage could result! Stay clear of fan exhaust while collector is operating. Note: Assembly with Tube Filters - Note plenum height requirements of Tube Filters - 6’ tubes - 8’ plenum / 8’ tubes - 10’...
  • Page 10: Fan / Blower Maintenance

    VII. Fan / Blower Maintenance 1. Electrical - 2. Cleanliness - 3. Safety - 4. Service - Notice - Wall Bracket Mounting Instructions 5 - 7.5 HP Direct Drive Owner’s Manual O.A.S. 2008...
  • Page 11: External Filter Maintenance

    VII. External Filter Maintenance Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! All steps should be done with a dust mask and eye protection and System off. The External Filter can be cleaned using the following methods: 1.
  • Page 12 VIII. Single and Three Phase Wire Diagram Use wiring diagram on motor plate if different from below. Wiring should always be done by a licensed electrician! - Electrically insulate all connections. - For counter-clockwise rotation, looking from top of motor down. 5hp Single Phase Baldor Motor / 230v / 19.5 amps / TEFC / C Face / 3450 rpm Top View...
  • Page 13 IX. Accessories Bin Level Monitor - AIB000000 - Bin Level Sensor Assembly w/ Strobe Light - AXB000000 Magnetic Motor Starters - Dust Bin Options - 1. Hoppers - 2. Air Locks - 3. Cone w/ Clean Out - 5 - 7.5 HP Direct Drive Owner’s Manual O.A.S.
  • Page 14: Troubleshooting

    X. Troubleshooting Motor Overheating The motor’s internal circuit breaker will trip if the motor is overheating. Poor Dust Pick-Up at Woodworking Machines Improper motor rotation - Running backwards will reduce suction by 30%. Filters filling with large chips and excessive dust Excessive vibration 5 - 7.5 HP Direct Drive Owner’s Manual O.A.S.
  • Page 15 XI. Fire Hazards - Read Before Installing and Operating Oneida Collectors are designed for WOOD DUST only!! Until this type of fire has been witnessed, it is difficult to believe the devastation. This type of fire is rare but worth safeguarding against. The following points are worth heeding: The customer assumes the responsibility for contacting their insurance underwriter with regard to specific application requirements of explosion venting or if additional fire protection and safety equipment may be...
  • Page 16: Terms And Conditions

    XIII. Terms and Conditions Checking in Order Limited Warranty *Note: Motors should be protected from extreme weather to prolong motor life. Single phase motors should only be started and stopped up to 4 - 10 times per hour. Starting single phase motors more frequently can cause heat build up and can cause the motor overload to trip or cause motor damage.
  • Page 17: Filter Efficiency Gauge Mounting Instructions

    XIV. Filter Efficiency Gauge Mounting Instructions Rectangular Plenum INCHES W.C. Mounting Instructions Elbow Plenum (Side View) Gauge Reading Instructions After many cleaning cycles, a filter’s pressure will rise after each cleaning. An older filter does not get as clean as a new filter. 5 - 7.5HP Direct Drive Owner’s Manual O.A.S.
  • Page 18: Fan Motor Lubrication

    XV. Fan Motor Lubrication every 5500 hours. Table 1 - Service Conditions Table 2 - Lubrication Interval Multiplier 5 - 7.5HP Direct Drive Owner’s Manual O.A.S. 2008...
  • Page 19 XVI. Supplemental Instructions for Magnetic Motor Starters with Oneida Air Systems Dust Collectors Please see complete manufacturer instructions for more information. You must have this product installed by a qualified and licensed electrician. The jumper is not required if you are using 3 phase power.
  • Page 20 5 - 7.5HP Direct Drive Owner’s Manual O.A.S. 2008...
  • Page 21 Note: Select Size of Fuse or Circuit Breaker Per Article 430.32 of the NEC (NFPA 70) 3O only Move this Wire to L2 for Single O White Plug - In Yellow Connector OL / Reset Brown Omit this Install this Jumper for Single O Using the Same Gauge Wire Wire for Sized &...

This manual is also suitable for:

Xxk070300

Table of Contents