Oneida Air Systems, Inc. was founded in 1993 to bring cost effective, state-of-the-art dust collection systems and material
handling ductwork to woodworking shops. OAS designs and manufactures industrial grade dust collection systems that
create a practical, safe and healthy work place environment.
Oneida Air Systems, Inc. a été fondée en 1993 pour mettre le coût, les systèmes état -of-the-art de dépoussiérage et de
manutention conduits efficace pour les ateliers de menuiserie. OAS conçoit et fabrique des systèmes de classe industri-
elle de la poussière de collecte qui créent un environnement pratique, sûr et sain lieu de travail.
2 & 3hp
Appearance may vary slightly /
L'apparence peut varier légèrement
ZBM000033

Advertisement

loading

Summary of Contents for Oneida Air Systems Dust Gorilla Portable XXP990201H

  • Page 1 Oneida Air Systems, Inc. a été fondée en 1993 pour mettre le coût, les systèmes état -of-the-art de dépoussiérage et de manutention conduits efficace pour les ateliers de menuiserie. OAS conçoit et fabrique des systèmes de classe industri-...
  • Page 2: System Start-Up Information

    System Start-Up Information Read the installation and maintenance instructions as well as the recommended safety practices in this manual. / Lisez les instructions d’installation et d’entretien ainsi que les pratiques de sécurité recommandées dans ce manuel. WARNING / AVERTISSEMENT Do not operate Fan / Blower unless Fan Housing is attached to DANGER Cyclone body and Dust Drum is in place.
  • Page 3 System Contents / le contenu du système Hardware List ASC000125 - Caulk Single (1) 1. BXI020108 - 2hp Motor Assembly or BXI030108 - 3hp Motor Assembly AFB025175 - Carriage Bolt 1/4”- 20 x 1.75” (9) 2. BHX001801 - Fan Housing (1) 3.
  • Page 4 All hardware may not be shown because of perspective. Check parts list for complete Bolt Washer Gasket amounts. / Tout le matériel ne peut être affi- Material Motor Plate chée car de perspective. Vérifiez la liste des pièces pour des montants complets. Housing Gasket Material...
  • Page 5 2 & 3hp Portable Collector The new Oneida Air Systems 2 & 3hp Portable dust collector offers you power and mobility at an ecomoni- cal price. Included with this collector are: Part # Description Patent pending Dust Sentry, an infrared bin level...
  • Page 6 Dimensions 35” Wire for the Dust Sentry™ 6” Dia. Inlet 77” 55” Gal. Steel Drum 6” 26” 33” 3” 48” Systems Electrical Data 200 to 240 volt single phase 20 amps. A 30 amp circuit breaker is recom- mended. (Similar to a clothes dryer.) / 200 à 240 volts monophasé 20 am- pères.
  • Page 7: Drum Assembly

    Assembly Instructions / Instructions de montage Drum Lid Assembly It is always good to have a qualified helper to assist you during assembly. Some parts are heavy and awk- 4. Apply 1” gasket around rim of the underside of drum ward to deal with.
  • Page 8: Leg Assembly

    Leg Assembly Figure 6. Position drum lid so the front 8. Slide foam hand grip onto top of bent front leg. You tab with the two may need some lubricant such as a little soapy water to holes that attach to help.
  • Page 9 11. Slide plastic cover on cord holder and attach to front Rear of gussett with 1.75” carriage bolts on front leg and either back leg as shown. You may have to carefully pull holder wider to fit bolt in bottom hole./ Glissez la couverture en plastique sur le support de cordon et fixer à...
  • Page 10 17. Apply 1/2” gasket around outside of bolt holes in cyclone top as shown, making sure there is no gap where ends butt together. / Appliquer 1/2 “joint autour de Figure 17 - l’extérieur de trous de boulons en haut de cyclone comme Apply gasket indiqué, en s’assurant qu’il n’y ait pas d’espace où...
  • Page 11 Note: Caution, filter must remain in place while system You must set the detection level on the sensor. It should is functioning to prevent access to the fan. / Attention, detect from 2” to 4” away depending on color and tex- ture of dust.
  • Page 12 27. Drum liner hold-down. (Retainer will come flat.) To as- semble Retainer use (6) provided plastic Push Pins. the outermost holes in the sheet (Fig. 1). Form the Retainer into a circle so the outside row of holes lines up. Put a Push Pin in from either side so the grabbing legs of the pins line up as shown in (Fig.
  • Page 13 Directions for Cleaning External Filter / Itinéraire pour nettoyage filtre externe All steps should be done with a dust mask and eye protection. Proper filter cleaning should not be neglected. A dirty filter can affect dust collector operation and filter life./ Toutes les étapes doivent être faites avec un masque anti-poussière et des lunettes de protection.
  • Page 14 Fan Motor Maintenance / Moteur de ventilateur Entretien Per Baldor specifications, their 2 pole motors (3,600 rpm) are to be relubricated every 5,500 hours. / Par spécifica- tions Baldor, leurs deux moteurs de pôles (3600 rpm) doivent être graissés toutes les 5500 heures. Table 1 - Service Conditions / Conditions de service Ambient Temperature Type of Bearing / Type...
  • Page 15: Troubleshooting / Dépannage

    Troubleshooting / Dépannage Note: If you continue to experience difficulty with your collector, call Oneida Air System's customer service at 866- 387-8822. / Si vous continuez à rencontrer des problèmes avec votre collecteur, appelez le service à la clientèle de Oneida Air System au 866-387-8822.
  • Page 16 Filter Clogging / Colmatage du Filtre Caused By / Causée Par: Large chips clogging th filter -Check for a leak in the dust bin, flex coupling or lid. Check for split or torn flex coupling. (See also: Motor Overheating sec- tion) -Make sure dust bin has not over filled.
  • Page 17 Fire Hazards / Risques D’incendie Read before installing and operating / Lire avant d’installer et d’exploitation. Wood shaping and cutting processes generate wood chips, shavings and dust. These materials are considered combus- tible. Air borne wood dust below 420 microns in size (0.17 of an inch) in certain concentration ranges when ignited can deflagrate (burn quickly).
  • Page 18 The customer assumes the responsibility for contacting their insurance underwriter with regard to specific application requirements of explosion venting or if additional fire protection and safety equipment may be required. / Le client assume la responsabilité de communiquer avec leur souscripteur d’assurance à l’égard des exigences spécifiques à l’application d’explosion ventilation ou si la protection incendie et équipements supplémentaires de sécurité...
  • Page 19 - Electrically ground all equipment and ducting. Static sparks can ignite wood dust. (Avoid using PVC drain pipe.) / Électriquement à la terre tout l’équipement et les conduits. Étincelles statiques peuvent enflammer la poussière de bois. (Évitez d’utiliser des tuyaux de vidange PVC.) - Don't allow accumulation of layers of fine dust on horizontal surfaces (especially overhead lights, electrical boxes and fuse panels which can ignite dust.) / Ne pas permettre l’accumulation de couches de poussière fine sur les surfaces horizontales (feux surtout les frais généraux, les boîtes électriques et des panneaux de fusibles qui peuvent enflammer la poussière.)
  • Page 20 In no event shall Oneida Air Systems’ liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga. / Bons Oneida Air Systems ™ les produits fabriqués par Oneida Air Systems, pour une période de 1 an ou plus selon le produit , à...
  • Page 21 Products will be shipped to Buyer’s single destination. Title and risk of loss shall pass to the Buyer upon delivery to such destination. Buyer pays transportation expenses. Dates of shipment are advisory and Oneida Air Systems will make reasonable efforts to ship on or before the date states for shipment, however, Oneida Air Systems shall not incur any liability for failure to ship on that date.