"Timer/min." operating mode

16
The "Timer/min." (1 - 10 minutes) operat-
ing mode could be used for the operation
of path illumination or staircase illumina-
tion (without security function), for exam-
ple.
After the button is pressed, the contact
closes according to the set time. The acti-
vation time can be set within the range of
1 to 10 seconds via the adjuster. The timer
function can be re-triggered, i.e. if switch-
ing occurs before the set time expires, the
set time restarts.
The "Timer/min." operating mode can be
assigned to the following buttons:
button of the home stations
• Floor-call button on the ET terminal of a
home station
• call button for flush-mounted and sur-
face-mounted door station
• call button for home stations
(left / right - same function)